4.5 Digital Torque
The drive can control a motor by using a
digital torque reference
.
The procedure is the following:
1
- Perform the
basic installation procedure (
see cap. 2.5 Basic installation on page 28 )
;
2
- Enable analog speed control via software interface:
a- Set the operative mode
3:Digital Torque
;
b- Insert the desired torque reference(*) in the window Torque Sat.;
c-
Save data to Eeprom
;
d- Enable/disable the drive by using the
Enable
/
Disable
buttons or 24V to the
D.IN1
(
ENABLE
) input.
(*) Insert the calculate torque reference using this formula
:
I
desired
x 100
I
peak
Example: Suppose we want to set a digital torque reference equal to 5A, having a drive size of 10/20
(10A=rated current, 20A=peak current)
insert in the window Torque Sat. the value 25, in fact
(5x100)/20=25.
The value 0,0% disable the function.