43
Switch-Back = On
A Input
B Input
A output
B Output
Good
Good
Input A
Input B
Fail
Good
Input B
Input A
Good
Good
Input A
Input B
Good
Fail
Input A
Input B
Good
Good
Input A
Input B
Switch-Back = BackUp_Fail
A Input
B Input
A output
B Output
Good
Good
Input A
Input B
Fail
Good
Input B
Input A
Good
Good
Input B
Input A
Good
Fail
Input A
Input B
Good
Good
Input A
Input B
Switching in
Combined mode
The following three tables apply when the switch is configured for Auto
switching. The
Inp-sel
setting is
auto
, the
Output-Config
is
Combined
and
Switch-Back
setting is varied for each of these tables.
Please read the table from top to bottom, this is the order of the events that
occur on the inputs.
Switch-Back = Off
A Input
B Input
A output
B Output
Good
Good
Input A
Input B
Fail
Good
Input B
Input B
Good
Good
Input B
Input B
Good
Fail
Input B
Input B
Good
Good
Input B
Input B
A Input
B Input
A output
B Output
Good
Good
Input A
Input B
Good
Fail
Input A
Input A
Good
Good
Input A
Input A
Fail
Good
Input A
Input A
Good
Good
Input A
Input A
Switch-Back = On
A Input
B Input
A output
B Output
Good
Good
Input A
Input B
Fail
Good
Input B
Input B
Good
Good
Input A
Input B
Good
Fail
Input A
Input A
Good
Good
Input A
Input B
A Input
B Input
A output
B Output
Good
Good
Input A
Input B
Good
Fail
Input A
Input A
Good
Good
Input A
Input B
Fail
Good
Input B
Input B
Good
Good
Input A
Input B