21
Clip_Level
Clip_Level
determines the level for full scale detection. This can be
set in a range from -6dBFS to 0dBFS. The default setting is -0.3 dBFS.
This is not a true peak (interpolated) measurement, but a straightforward
level comparison.
Silence_Det
Silence_Det
allows the card to detect whether the signal has any
PCM channels which have silence for the given
Silence-time
and
Silence-level
.
Off
: the functionality is switched off.
Probe
: the card detects if there is PCM silence, but will only give
this as a status item. The card will not switch to the other channel.
A
: the card detects PCM silence on channel A and will switch to the
other channel.
B
: the card detects PCM silence on channel B and will switch to the
other channel.
A+B
: the card detects PCM silence on both channel A and B and will
switch to the other channel.
The default setting is
Probe
Silence_Time
If the embedded audio contains silence, this can be reported by the GIX-
HIX100-110. This setting allows you to determine how many seconds it
takes before the card reports the silence
.
This setting can be set in a
range from 1 sec to 255 sec. The default setting is 10sec.
Silence-Level
Silence-level
determines the value that triggers a silent alarm. The
silence threshold can be set between –100 and -20 dBFS. Default is –60
dBFS .
SYNCHRONIZE
Dly_Frmt_Prst
With
Dly_Frmt_Prst
you can edit the delay values for the various
video formats. This works as presets. All settings with a #-prefix are part
of the preset. Set this to the video format for which you want to adjust
the delay of the synchronizer. This setting is only used to display the
correct delay settings. Possible settings are:
1080p60
,
1080p50
(GIX only)
1080i60
,
1080i50
1080p30
,
1080p25
1080p24
,
1080p24sf
720p60
,
720p50
SD525
,