![Axminster Trade AT254PS13 Manual Download Page 36](http://html.mh-extra.com/html/axminster-trade/at254ps13/at254ps13_manual_3040370036.webp)
Changing the Saw Blade
36
7. Replace the kerf plate and inner guard assembly. Slide
the table back until the locking knob pin engages the pin
recess. Turn the saw blade once by hand to check it spins
freely and replace the crown guard. When everything is
satisfactory, reconnect the machine to the mains supply.
Give the machine a test run ( i.e. quick ON-OFF) to
ensure everything is OK. If everything is satisfactory,
continue to use the panel saw.
Routine Maintenance
• Keep the saw as clean and free from saw dust build up
as practical.
• Periodically, unlock the sliding table and push to one
side and remove the inner guard to gain access to
the saw mechanism. Raise the saw blade to it’s high-
est point, remove the crown guard and blow, brush or
vacuum out the saw inner workings, using a proprietary
resin cleaner.
• Check the saw blade regularly for chipped ,missing,
damaged teeth etc. and remove any resin build up from
the blade/s, riving knife etc.
• After several months of constant use the condition of
the chains, sprockets, tension of the drive belts and the
threaded drive shafts of the rise and fall tilt mechanisms
will need to be checked; that may require a service
engineer to oversee the job.
• If you find that the machine is not performing as
it should please contact our “Specialist After Sales
Team” by phone on 03332 406 406 or visit our
website at axminster.co.uk.
• If the “Panel Saw” is not going to be used for a period
of time, spray a light coat of oil over the table surface
and blades that will help prevent rust.
General Information
Sliding Table (Side Play Movement)
After several months of use, if you notice the sliding
table shows signs of ‘slide play’ movement follow the
instruction below.
WARNING!! DISCONNECT THE MACHINE
FROM THE MAINS BEFORE CONTINUING!
1. Pull the sliding table locking knob towards you and
slide the table to the side exposing the cap head screws
beneath, see 128.
2. Adjust each screw in turn, (one rotation) should be
sufficient. Slide the table to the opposite end and repeat
the procedure. Check the table to see that the slide play
has been queried. If OK, re-lock the table.
Fig 128
Cap head screw
WARNING!! DISCONNECT THE MACHINE
FROM THE MAINS BEFORE CONTINUING!
Inspecting and Changing the Drive Belts
Check the blade drive belts for any signs of wear
including fraying, stretching, missing teeth and basic
wear and tear etc. Follow the instructions below.
1. Slide the table to one side and remove the crown
guard and inner guard, place safely aside.
2. Remove the main blade, as instructed on page 35.
3. Remove the fixing that secures the extractor housing
assembly, see figs 129 place them safely aside and lower
housing assembly down to the floor.
Main Saw Blade
Fig 129
Cap head bolt
Summary of Contents for AT254PS13
Page 1: ...AT254PS13 Panel Saw Code 508339 AT M 30 03 2020 BOOK REF 101153 BOOK VERSION 2 ...
Page 4: ...What s Included 4 11 23 10 28 19 9 7 8 30 16 6 2 27 17 13 2 2 28 3 5 4 22 24 26 12 14 15 ...
Page 21: ...Machine Footprint 21 3 210mm 3 720mm 1 120mm 1 Metre extension ...
Page 39: ...Exploded Diagrams Lists 39 DIAGRAM A Continues over ...
Page 41: ...Exploded Diagrams Lists 41 DIAGRAM B Continues over ...
Page 43: ...Exploded Diagrams Lists 43 DIAGRAM C Continues over ...
Page 45: ...Exploded Diagrams Lists 45 DIAGRAM D Continues over Continues over ...
Page 47: ...Exploded Diagrams Lists 47 DIAGRAM E Continues over ...
Page 49: ...Notes 49 ...
Page 50: ...Notes 50 ...
Page 51: ...Notes 51 ...