5 Assembly in-roof system
In-roof System
Page 36 / 64
EN141217 Axitec GmbH, Otto-Lilienthal-Str. 5, 71034 Böblingen, Germany, +49 (0)7031 62 88-5186
5.3
Cable laying
NOTE
Lay the continuous cable and connection cable before mounting
of the modules.
Do not connect modules in vertical strands: The modules can
have different temperatures and thus contain power.
When wiring the strands avoid induction loops.
All connecting cables should be fixed properly between the
module and the under-roof membrane compartment (cable
channel).
NOTE
For the cabling of the photovoltaic system, only mechanically stable,
high voltage resistant, UV resistant, ozone steady and temperature
steady solar cables are allowed. These are not included in the delivery.
1.
Connect continuous connection cable at the first module and/or
lowest module of the strand.
2.
Connect the modules in horizontal strands with connecting cables
and connectors.
3.
Connect the module rows with the connection cable.
4.
With exposed locations observe lightning protection measures.