UMAX0608XX‐1000. Tri‐Axial J1939 CAN Inclinometer. Version 9B
Page: 59-66
Inclinometers with the same enclosure, see Table 25, have a different part number on the label
and can have a different pinout and a unit orientation.
Use mating connectors compliant with IEC 61076-2-101:2012.
If only one connector is used, an M12 sealing cap with IP67 rating should be installed on the
unused connector. PROT-M12 FB – 1555538 from PHOENIX CONTACT is recommended for
the unused output M12 connector, Axiomatic P/N AX070140.
6.7.1.1 Connector Pinout
Inclinometers in AX060800 enclosure have two versions of the pinout.
6.7.1.1.1 CAN Only
The CAN only pinout is used in inclinometers: AX060800, AX060808, AX060830, AX060838
that do not have any other interfaces but CAN, see Figure 40.
Figure 40. AX060800 Connector Pinout
There is only one CAN port supported by the units. Both CAN connectors are physically
connected together to facilitate cable routing in the user’s system.
A mating plug with CAN termination, P/N: AX070114, can be ordered for applications requiring
termination of the CAN network on the unit.
6.7.1.1.2 CAN and Analog Signal Outputs
Inclinometer AX061000 in addition to CAN interface has 3 analog signal outputs, see Figure
41.
Figure 41. AX061000 Connector Pinout