6 TECHNICAL SPECIFICATIONS
6.1 Performance
Parameters
Stated at 25°C unless otherwise specified.
6.1.1 Angular Measurements
Table 18. Angular Measurement Parameters
Parameter
Value
Remarks
Measurement Range
±180° – Pitch & Roll
0…180° – Gravity
±90° default for Pitch & Roll
1
AX060800, AX060806, AX060807,
AX060808
Resolution
0.35°
Effective Resolution (3.46*NoiseRMS).
Maximum, at cut-off frequency Fc=5Hz
Initial Accuracy
±2°
Maximum
Temperature Drift
±3.5°
Maximum, in the full temperature range:
-40…85°C
Nonlinearity
±0.7%
Maximum
Cross-Axis Sensitivity ±3.5%
Maximum
Cut-off frequency, Fc 1…50 Hz,
5 Hz default
User-selectable
AX060830, AX060838, AX060810, AX060811, AX061000
Resolution
0.06°
Effective Resolution (3.46*NoiseRMS).
Maximum, at cut-off frequency Fc=5Hz,
accelerometer range 1.5g
Initial Accuracy
±2°
Maximum
Temperature Drift
±3°
Maximum, in the full temperature range:
-40…85°C
Nonlinearity
±0.1%
Maximum
Cross-Axis Sensitivity ±1%
Maximum
Cut-off frequency, Fc 1…50 Hz,
5 Hz default
User-selectable
1
±90° Pitch & ±180° Roll defaults for AX060808, AX060838.
6.2 Power Supply Input
Table 19. Power Supply
Parameter
Value
Remarks
Supply Voltage
9…36 VDC
12V, 24V – nominal
Protection
Reverse polarity,
Transients
AX060800, AX060806, AX060807, AX060808, AX060830, AX060838, AX060810, AX060811
Supply Current
1
15 mA
25 mA
Maximum at 24V
Maximum at 12V
AX06100
Supply Current
1
50 mA
110 mA
95 mA
Maximum at 24V. All signal outputs are in
Voltage
Output
mode.
Maximum at 24V. All signal outputs are in
Current
Output
mode at 24mA output current.
Maximum at 12V. All signal outputs are in
Voltage
Output
mode.