![AXIOMATIC Tri-Axial J1939 CAN User Manual Download Page 58](http://html1.mh-extra.com/html/axiomatic/tri-axial-j1939-can/tri-axial-j1939-can_user-manual_3037103058.webp)
UMAX0608XX‐1000. Tri‐Axial J1939 CAN Inclinometer. Version 9B
Page: 58-66
Table 24. EMC Compliances
Standard Name
Description
AX060800, AX060808, AX060830, AX060838
EN 13309:2010
Construction Machinery. Electromagnetic Compatibility of Machines with
Internal Electrical Power Supply
6.6 Inclinometer
Modifications
Table 25. Inclinometer Modifications
P/N
Enclosure Connectors
Internal CAN
Terminating Resistor
Sensor
AX060800
AX060800 Two M12 Connectors
No
Regular
AX060808
1
AX060806
AX060806
4-pin Deutsch DT15-4P
connector
AX060807
Yes
AX060830
AX060800 Two M12 Connectors
No
High-
performance
AX061000
AX060838
1
AX060810
AX060806
4-pin Deutsch DT15-4P
connector
AX060811
Yes
1
Legacy product with vertical original unit frame orientation. Starting from firmware V5.0, the unit frame
orientation is configurable.
6.7 Enclosures
6.7.1 AX060800
The AX060800 inclinometer has a cast aluminum enclosure with two 5-pin M12 A-coded round
connectors, see Figure 39.
Figure 39. AX060800 Dimensional Drawing