UMAX0608XX‐1000. Tri‐Axial J1939 CAN Inclinometer. Version 9B
Page: 32-66
In user applications, to avoid errors, it is recommended checking the new unit frame orientation
on the bench before installing the inclinometer on the machine. The Axiomatic CAN Assistant –
Visual, P/N: AX070501VIS can be used to verify angular directions and ranges after
performing the unit frame coordinate rotation.
3.5 Sensor
Calibration
The
Sensor Calibration
function block presents internal calibration read-only parameters. It
does not have any signal inputs and outputs.
Sensor Calibration
Figure 17. Sensor Calibration
The calibration parameters can be inspected in the field by a qualified technician. They are
also written in a setpoint file together with other configuration parameters.
3.6 Binary
Functions
There are ten
Binary Function
blocks available to the user for performing simple data
conversions. Each
Binary Function
block has two continuous signal inputs and one continuous
signal output.
Binary Function
#1...10
X
1
X
2
Y
Figure 18. Binary Function Block
The
Binary Function
block performs the following data conversion:
𝑌
𝐴 ∙ 𝐹 𝑎 ∙ 𝑓 𝑋
𝑏 ; 𝑎 ∙ 𝑓 𝑋
𝑏
𝐵, 𝑛
1,2;
(10)
where
:
𝑋
–
Input signal;
𝑓 𝑋
–
Unary function;
𝑎
–
Scale;
𝑏
–
Offset;
𝐹 𝑥; 𝑦
–
Binary Function;
𝐴
–
Output Scale;
𝐵
–
Output Offset.
The function block input signals can be undefined. The user can specify a default signal value
that will be used when the signal is not defined. If the default signal value is not specified, the
output signal of the function block will become undefined too.
The following unary functions can be used to process the input signals.