![AXIOMATIC Tri-Axial J1939 CAN User Manual Download Page 41](http://html1.mh-extra.com/html/axiomatic/tri-axial-j1939-can/tri-axial-j1939-can_user-manual_3037103041.webp)
UMAX0608XX‐1000. Tri‐Axial J1939 CAN Inclinometer. Version 9B
Page: 41-66
Name
Default
Value
1
Range
Units
Description
Signal #1 Size
16
[1…32]
bit
Size of the 1-st CAN output
signal
Signal #1
Resolution
0.002
Any value
signal
units /
bit
Resolution of the 1-st CAN
continuous output signal
Signal #1Offset
-64
Any value
signal
units
Offset of the 1-st CAN
continuous output signal
Signal #2 Type
Continuous {Undefined, Discrete,
Continuous}
–
Type of the 2-nd CAN
output signal
Signal #2 Source
Roll Angle
Any signal output of
any function block or
“Not Connected”
–
Input signal source of the 2-
nd CAN output signal
Signal #2 Byte
Position
3
[1…8]
–
Byte position of the 2-nd
CAN output signal
Signal #2 Bit
Position
1
[1…8]
–
Bit position of the 2-nd CAN
output signal
Signal #2 Size
16
[1…32]
bit
Size of the 2-nd CAN output
signal
Signal #2
Resolution
0.002
Any value
signal
units /
bit
Resolution of the 2-nd CAN
continuous output signal
Signal #2Offset
-64
Any value
signal
units
Offset of the 2-nd CAN
continuous output signal
…
…
…
…
…
Signal #10 Type
Undefined
{Undefined, Discrete,
Continuous}
–
Type of the 10-th CAN
output signal
Signal #10 Source
Not
Connected
Any signal output of
any function block or
“Not Connected”
–
Input signal source of the
10-th CAN output signal
Signal #10 Byte
Position
1
[1…8]
–
Byte position of the 10-th
CAN output signal
Signal #10 Bit
Position
1
[1…8]
–
Bit position of the 10-th
CAN output signal
Signal #10 Size
1
[1…32]
bit
Size of the 10-th CAN
output signal
Signal #10
Resolution
1
Any value
signal
units /
bit
Resolution of the 10-th CAN
continuous output signal
Signal #10 Offset
0
Any value
signal
units
Offset of the 10-th CAN
continuous output signal
1
For CAN Output Message #1.
2
Yes – in firmware V1.xx for AX060800, AX060806, AX060807.
3
Proprietary A PGN (61184) is excluded. It is taken by Axiomatic Simple Proprietary Protocol and
therefore cannot be used in function blocks.
Configuration parameters:
Signal #1…10 Byte Position
and
Signal #1…10 Bit Position
,
together with the
Signal #1…10 Size
have the same meaning as in the
CAN Input Signal
function block. The user should be careful not to overlap the output signals.