Version 3.0.0 Preliminary Documentation – May be Subject to Change 28-46
Object Description
Index 2090h
Name
AI Measuring Window
Object Type
ARRAY
Data Type
UNSIGNED16
Entry Description
Subindex 0h
Description
Number of entries
Access RO
PDO Mapping
No
Value Range
8
Default Value
8
Subindex
1h to 8h
Description Measuring
Window
Access RW
PDO Mapping
Yes
Value Range
Sensor Type Frequency:
10 to 10000 [ms]
Sensor Type 16-Bit Counter:
1 to 65535 [pulses]
Default Value
1000
3.3.4. Object 20A0h: AI Enable Error Checking 8 Input Lines
This object enables or disables the input error-checking feature for each input configured for
“Normal” operation by object 6112h. If the input is configured as a 16-bit counter or a digital
input, error checking is automatically disabled.
Object Description
Index 20A0h
Name
AI Enable Error Checking 8 Input Lines
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Subindex 0h
Description
Number of entries
Access RO
PDO Mapping
No
Value Range
1
Default Value
1
Subindex 1h
Description
Error Check for AI 1 = Bit 1 to AI 8 bit 8
Access RW
PDO Mapping
No
Value Range
Bit Value 0 = Error Check Disabled
Bit Value 1 = Error Check Enabled
Default Value
00h (all error check disabled)