![axing EoC 10-01 Operation Instructions Manual Download Page 82](http://html1.mh-extra.com/html/axing/eoc-10-01/eoc-10-01_operation-instructions-manual_3036642082.webp)
Operation Instructions | EoC 10-01 | Ethernet over Coax | Master
40
2018-06-25 | Technical improvements, changes in design, printing- and other errors expected.
5.6. Led Indicator
∂
Power
∂
Ethernet LAN Link/Activity per Port
∂
EoC Link/Activity
∂
EoC Connection Quality
∂
EoC Endpoint Diagnosis
∂
SFP Link
5.7. NMU & Master Device
∂
Network Management Unit(NMU) Support multiple EoC Master Devices
∂
Built-in one EoC Master Device
5.8. Endpoint Device
∂
Cooperate with EoC 10-02
∂
Support up to 31 Endpoints per EoC Master
5.9. Power Requirement
∂
12V DC Input
∂
Line Power from Coax: 60VAC +/- 20%
∂
Line Power from IEEE802.3af PoE (37~57V) via port LAN2
∂
Power Consumption: < 5 Watts
5.10. Environmental Condition
∂
Operation: -10
℃
~55
℃
(14
℉
~131
℉
)
∂
Storage: -10
℃
~ 65
℃
(14
℉
~149
℉
)
∂
Humidity: 10% ~ 95% Non-condensing
5.11. Physicals
∂
Dimensions: 178(W) x 136(D) x 35(H) mm
∂
Weight: 375 g