A
XELL
BSF-4004
BSF0038
S
ERIES
R
EPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
3.2.3 Mount the Repeater on the Wall
The Repeater wall mount brackets assembly should be fixed to a solid wall (these include brickwork,
blockwork, and concrete.);
(Due to the weight of the Repeater, it is NOT recommended to fix to a hollow wall).
Figure
3-7: M6 Rawlbolt – recommended for wallmount.
IMPORTANT!
Always check that there are no pipes or cables hidden in the wall beneath the area to be drilled.
Various pipe and cable detectors are available for this type of inspection.
To provide secure fixing to a solid wall, the most common method is drilling and plugging. The size
of fixing is dependent on the item to be fixed and the nature of the wall, The Repeater should be fixed
with mild steel, M6 (50mm to 75mm) rawlbolts or similar.
1. Mark out the fixing centres of the repeater on the chosen wall (see
3.2.2).
2. Mark and drill the wall with the correct size masonry bit as specified by the fixing manufacturer.
Note: It is good practice to wear goggles to protect your eyes from flying debris when using power
tools.
3. Hold the drill bit against the mark and begin drilling slowly so that the bit does not wander from
the position. The wall should be drilled to a depth which is sufficient to accommodate the full
length of the fixing.
4. Insert the fixings so that the top of the sleeve/anchor section is level with the wall surface.
5. Gently tighten the bolt by hand so that the anchor section of the fixing expands and grips the
inside of the hole.
Figure
3-8: Inserting Fixing and Tightening.
50 -
75mm
6
mm dia
.
Bolt head
Washer
Sleeve/Anchor
© Axell Wireless Ltd
Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0
5