A
XELL
BSF-4004
BSF0038
S
ERIES
R
EPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
Column
Description
Pos
Each Rack corresponds to an OMU unit whereas each Slot
corresponds to an Opto-Module. Slots are numbered according to their
position in the OMU Chassis (numbered
left to right
).
Select All
Batch selection options:
- mark all remotes for UL opto-adjustment.
- mark all remotes for DL opto-adjustment.
- mark all remotes for DL
and
UL adjustment.
Node
Node list number and identification (e.g. AHFK)
Status
Displays an Error if process failed. If successful the pilot tone used
and the adjustment level will be displayed.
Resulting Attenuation
Compensation level used for the opto-module (in dB).
9. Mark the check-boxes corresponding to the remotes (each connected to the designated Opto-
module/Opto-Splitter) to which to perform the adjustment.
10. OLA (DL/UL) may be performed on each node individually (or a batch) or on
all
nodes at once
by marking the checkbox next to the desired corresponding Opto-module and clicking
Adjust
.
To easily mark all checkboxes mark the checkbox named
OLA
.
NOTE: The process may take several minutes depending on the size of the system and remote
distance.
© Axell Wireless Ltd
Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0
21