A
XELL
BSF-4004
BSF0038
S
ERIES
R
EPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
7. Inspect the fibre connector using a Fibrescope. On the PC monitor, verify that there is no
contamination present on the connector end-face.
8. If the connector is dirty, clean it with a wet cleaning technique followed immediately by dry
cleaning. This is to remove any remaining residue from the wet clean (the following steps
demonstrate a wet cleaning technique).
Wet Cleaning
ATTENTION!
Invisible laser radiation might be emitted from disconnected fibers or
connectors. Do not stare into beams or view directly with optical
instruments.
1. Lightly moisten a new lint-free wipe with 99% isopropyl alcohol. (Step 1 below).
Tip: Have a dry lint-free swab available for immediately drying after performing the wet-cleaning.
2. Lightly press and turn a clean lint-free swab in the moistened area of the wipe to moisten the
swab. It is important that the swab is not too wet. (Step 2 below).
3. Insert the moistened lint-free swab into the bulkhead adapter. Lightly press and rotate several
times in the same direction. (Step 3 below).
Wet-Cleaning Technique
4. Immediately use a dry lint-free swab to clear any remaining alcohol residue.
NOTE: Do not re-use any of the wipes and/or swabs. Dispose of them properly.
5. Follow steps 3 to 6 of Dry Cleaning above
6. Re-inspect the fibre using the Fibrescope. On the PC monitor, verify that there is no
contamination present on the connector end-face.
7. If the fibre is still dirty, go back to step 1 (Wet Cleaning) and repeat the entire process.
NOTE: The entire wet/dry cleaning cycle should only be used twice, if the fibre is still dirty after two
cycles of wet/dry cleaning seek advice from the Axell Wireless Support Desk.
Step 1
Step 2
Step 3
© Axell Wireless Ltd
Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0
57