PRODUCT DESCRIPTION AND USER’S MANUAL
5.4.2 Modem Setup
NOTE: This section is relevant only if a modem is installed in the system. If connecting directly via
Ethernet, see section 5.4.1.
The BSF-4004 can operate over two types of modem: Packet Switched (GPRS, GSM etc.) or Circuit
Switched (PSTN/GSM). The available options depend on the modem type installed in your system.
Modem Setup Overview
1. Insert the SIM card in the modem SIM slot (if using a wireless modem).
2. Click the
Config
button and then select
Remote Communication
from the displayed icons. The
following dialog appears.
3. Verify that
Remote
Communication
is
ON.
4. Select the
Device:Method –
communication method. Select the option relevant to your installed
modem. (STD:DTC = Standard AT:Data Call, ETH:TCP = Ethernet:TCP connection)
5. Configure your communication method according to the relevant following section.
5.4.2.1 Packet Switched Modem Configuration (GSM/GPRS)
NOTE: In case network attach is not done properly (using GPRS), it is necessary to telnet, SSH or
serial into the controller and enter TRACE MODEM to see why modem is not initialized (wrong /
missing PIN, wrong APN etc).
•
From the Remote communication menu, select
TRM-3 GPRS
.
•
In the GRPS area, enter the following:
•
Access Point Name – customer’s Access Point name.
•
Click
Apply
.
36
Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0
© Axell Wireless Ltd