3.7.2.3 230 VAC Power Source
Connect the power cable to the plinth as show below:
•
Phase
linked to the
brown
cable
•
Neutral
linked to the
blue
•
Ground
to the
yellow/green
. See illustration below.
Figure
3-17: 230 VAC Power Connections
3.7.2.4 115 VAC Power Source
Cable requirements:
•
Cable should be NRTL (safety) approved with a minimum of 14AWG (2.5mm) per conductor.
•
For safety, the GND cable must be
10mm longer
than the Phase and Neutral cables.
Connect the power cable to the plinth as show below:
•
Phase
linked to the
Black
cable
•
Neutral
linked to the
White
•
Ground
to the G
reen
where for SAFETY, the GND cable must be
10mm longer
than the Phase
and Neutral cables.
Figure
3-18: 115VAC Power Connections