A
XELL
BSF-4004
BSF0038
S
ERIES
R
EPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
3.5 Fibre Optic Connection
Class 1 Laser
This product is equipped with class 1 lasers, as per definition in EN 60825-1.
Caution!!!
Un-terminated optical receptacles may emit laser radiation.
Do not stare into beam or view with optical instruments.
Use the following over the complete link between the Repeater and OMU:
•
Use angled APC connectors at 8deg angle
•
APC type ODF connections
•
Mono-mode type fibre
Connecting the Fibre Optic Cable
1. Select type of optic fibre (Recommended fibre cable is single mode 9/125).
2. Run the fibre through a corrugated sleeve (not supplied).
3. Insert the optic fibre hose fitter (may be pre-assembled) and route the fibre cable(s) via the Fibre
input (see front panel interfaces in section
1.5.2).
10
Doc. No. PN 4004 BSF0038 Series-UM Rev. 1.0
© Axell Wireless Ltd