RJ45 to Mini DIN-8 plug
The Avonic AV-CON300-IP comes with a single RS232 connecting cable with RJ45 plug to Mini DIN-8 plug.
With this cable only 1 channel can be connected to the controller. This channel can control up to 7 (VISCA) or
up to 10 (PELCO) cameras. The Mini DIN 8 connector is used for RS232.
To control the cameras assigned to the other channels, more RJ45 cables are required.
Connect the cable using the diagram below:
Figure 4: RJ45 to Mini DIN-8 plug diagram
RS-485 Interface
It is possible to connect a 5-pins Phoenix connector to the controller using a cable to a 2-pins Phoenix
connector. This 2-pins Phoenix connector can be connected to the RS485 interface on the camera.
Note that this is only possible for the camera(s) assigned to channel 1.
1.
RS422 (-)
2.
RS422 (+)
3.
GND (G)
4.
RS485 (-)
5.
RS485 (+)
COM port settings
In default working mode, an Avonic camera is able to connect to the CON300-IP controller with RS-232 or
RS-485 serial interface.
The camera can be controlled via RS-232, the parameters of RS-232C are as follows:
• Baud rate: 2400/4800/9600/115200
• Start bit: 1 bit.
• Data bit: 8 bits.
• Stop bit: 1 bit.
• Parity bit: none.
User Manual AV-CON300-IP
| www.avonic.com
15