IFD5XX Installation Manual
600-00299-000
Page 97 of 198
Revision: 02
SPR Flag (LAT/VRT Super Flag)
Selection
Description
Hidden
The lateral and vertical flag on the external indicator is hidden
In view
The lateral and vertical flag on the external indicator is in view
Table 82: NAV Superflag Test Page
TO-FROM
Selection
Description
From
The From flag on the external indicator is in view
Hidden
The TO/FROM flag on the external indicator is hidden
TO
The TO flag on the external indicator is in view
Table 83: Navigation TO/FROM Page
Selected Course
This section will calibrate the external CDI/HSI to the IFD5XX.
1.
Select 150° on the CDI/HSI;
2.
Verify the Selected Course is displayed on the IFD5XX and press the ENTR button on
the IFD5XX;
3.
After calibrating, verify 30° increments on the CDI/HSI are properly displayed on
the IFD5XX ±2 .
DME Channel Mode
This configuration allows you to set the format for the DME tuning data output.
Selection
Description
UNINSTALLED
No DME installed/configured
King Serial
King Serial DME tuning
Parallel 2x5
2 of 5 parallel DME tuning
Parallel BCD
Shifted BCD (Binary Coded Decimal) parallel DME tuning
Parallel Slip
Slip-code parallel DME tuning
Narco 890/891
2 of 5 parallel DME tuning, compatible with the following DME
units:
Narco DME 890
Narco DME 891
ARC (Cessna) RTA-476A
Table 84: DME Channel Mode