NOTES:
1. ALL WIRES TO BE 24 AWG OR GREATER UNLESS OTHERWISE NOTED.
2.
AT IFD540 UNIT, TERMINATE SHIELD GROUNDS TO THE CONNECTOR BACKSHELL OR USE
CARD-EDGE CONNECTOR TO TERMINATE SHIELD GROUNDS TO BACK PLATE. THE SHIELD LEADS
MUST BE LESS THAN 3.0 INCHES. CONNECT OTHER SHIELD GROUNDS TO AIRCRAFT CHASSIS
WITH AS SHORT A CONDUCTOR AS PRACTICAL.
3.
IF THE GPS ARINC 429 IN 1 PORT (P1001-48 AND -49) IS ALREADY USED FOR ANOTHER PURPOSE,
THE GPS ARINC 429 IN 2 PORT (P1001-50 AND -51) MAY BE CONNECTED INSTEAD.
4.
REFER TO SECTION 7 FOR ARINC 429 CHANNEL SETTINGS.
5.
REFER TO SECTION 7 FOR RS-232 CHANNEL SETTINGS.
6.
REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPELTE PINOUT AND INTERCONNECT
INFORMATION. PINOUTS OF OTHER UNITS SHOWN FOR REFERENCE ONLY.