IFD5XX Installation Manual
600-00299-000
Page 156 of 198
Revision: 02
IFD540 #1
SERIAL DME DATA
SERIAL DME CLOCK
SER DME-CHAN REQ/PAR DME-4MHZ
DME COMMON
SER DME-RNAV MODE/PAR DME-2MHZ
P1006
19
18
20
22
21
IFD540 #2
SERIAL DME DATA
SERIAL DME CLOCK
SER DME-CHAN REQ/PAR DME-4MHZ
DME COMMON
SER DME-RNAV MODE/PAR DME-2MHZ
P1006
19
18
20
22
21
KN 62/ 62A
KN 64
P621/ P62A1
P641
Bendix/ King
13
14
L
13
14
L
N/C
NAV 1
NAV 2
C
C
DME
DATA BUS
CLOCK BUS
RNAV/CHANNEL REQUEST
DME COMMON
N/C
NOTES:
1.
ALL WIRES TO BE 24 AWG OR GREATER UNLESS OTHERWISE NOTED.
2.
AT IFD540 UNIT, TERMINATE SHIELD GROUNDS TO THE CONNECTOR BACKSHELL OR USE CARD-EDGE CONNECTOR TO
TERMINATE SHIELD GROUNDS TO BACK PLATE
– THE SHIELD LEADS MUST BE LESS THAN 3.0 INCHES. CONNECT OTHER
SHIELD GROUNDS TO AIRCRAFT CHASSIS WITH AS SHORT A CONDUCTOR AS PRACTICAL.
3.
THE IFD540 MUST BE CONFIGURED AT INSTALLATION TO OUTPUT KING SERIAL DME TUNING DATA UNDER THE DME CHANNEL
MODE.
4.
REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND INTERCONNECT INFORMATION. PINOUTS OF
OTHER UNITS SHOWN FOR REFERENCE ONLY.
3
3
3
Figure D - 20: King Serial DME Tuning Interconnect, Panel Mount
Summary of Contents for IFD540