IFD5XX Installation Manual
600-00299-000
Page 142 of 198
Revision: 02
IFD540
P1001
46
47
48
49
24
23
GPS ARINC 429 OUT A
GPS ARINC 429 OUT B
GPS ARINC 429 IN 1A
GPS ARINC 429 IN 1B
VOR/ILS 429 OUT A
VOR/ILS 429 OUT B
P1006
SANDEL SN3500
P2
31/(2)
17/(32)
30
15
3/(35)
33/(21)
GPS ARINC 429 IN A
GPS ARINC 429 IN B
GPS ARINC 429 OUT A
GPS ARINC 429 OUT B
NAV ARINC 429 IN A
NAV ARINC 429 IN B
NOTES:
1.
ALL WIRES TO BE 24 AWG OR GREATER UNLESS OTHERWISE NOTED.
2.
AT IFD540 UNIT, TERMINATE SHIELD GROUNDS TO THE CONNECTOR BACKSHELL OR
USE CARD-EDGE CONNECTOR TO TERMINATE SHIELD GROUNDS TO BACK PLATE
–
THE SHIELD LEADS MUST BE LESS THAN 3.0 INCHES. CONNECT OTHER SHIELD
GROUNDS TO AIRCRAFT CHASSIS WITH AS SHORT A CONDUCTOR AS PRACTICAL.
3.
REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT
INFORMATION AND CONFIGURATION.
3
Figure D - 8: Sandel SN3500 Interconnect