IFD5XX Installation Manual
600-00299-000
Page 157 of 198
Revision: 02
IFD540 #1
SERIAL DME DATA
SERIAL DME CLOCK
SER DME-CHAN REQ/PAR DME-4MHZ
DME COMMON
SER DME-RNAV MODE/PAR DME-2MHZ
P1006
19
18
20
22
21
IFD540 #2
SERIAL DME DATA
SERIAL DME CLOCK
SER DME-CHAN REQ/PAR DME-4MHZ
DME COMMON
SER DME-RNAV MODE/PAR DME-2MHZ
P1006
19
18
20
22
21
KDI 572
KDI 574
P5721
P5741
Bendix/ King
11
12
17
33
48
49
15
11
12
17
33
48
49
15
N/C
DME
DATA BUS
CLOCK BUS
RNAV REQUEST
10 BIT/50 BIT SELECT
NAV 1 COMMON
NAV 2 COMMON
DME REQUEST
N/C
NOTES:
1.
ALL WIRES TO BE 24 AWG OR GREATER UNLESS OTHERWISE NOTED.
2.
AT IFD540 UNIT, TERMINATE SHIELD GROUNDS TO THE CONNECTOR BACKSHELL OR USE CARD-EDGE CONNECTOR TO TERMINATE
SHIELD GROUNDS TO BACK PLATE
– THE SHIELD LEADS MUST BE LESS THAN 3.0 INCHES. CONNECT OTHER SHIELD GROUNDS TO
AIRCRAFT CHASSIS WITH AS SHORT A CONDUCTOR AS PRACTICAL.
3.
THE IFD540 MUST BE CONFIGURED AT INSTALLATION TO OUTPUT KING SERIAL DME TUNING DATA UNDER THE DME CHANNEL MODE.
4.
REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND INTERCONNECT INFORMATION. PINOUTS OF OTHER
UNITS SHOWN FOR REFERENCE ONLY.
3
DME
KN 63
KDM 706
P631
P7061
Bendix/ King
6
F
D
9
8
24
N/C
DATA BUS
CLOCK BUS
DME REQUEST
3
3
Figure D - 21: King Serial DME Tuning Interconnect, Remote Mount
Summary of Contents for IFD540
Page 1: ......
Page 198: ...600 00299 000 Copyright 2014 Avidyne Corporation Rev 02 ...