![Avid Technology SMARTCAL Installation And Operation Manual Download Page 16](http://html1.mh-extra.com/html/avid-technology/smartcal/smartcal_installation-and-operation-manual_3031393016.webp)
CRANE
CO.
280
N.
MIDLAND
AVE.,
STE
258,
SADDLE
BROOK,
NJ
07663
WWW.AVIDCONTROLS.COM
12/17/12
TECH-440/D.W.O. 23135
Page 16 of 55
Step 1.
Mount the magnet assembly and bracket to the actuator as described in Section
3.3 Step 1.
Step 2.
Mount the position sensor housing so that the conduit entry faces away from the
diaphragm or cylinder. (See Figure 3-7)
Figure 3-7
Note:
For Fisher actuators model 657 & 667 sizes 34 thru 70, a slotted mounting kit
design can be supplied to ease the mounting process. This will allow the user to easily
center the positioner sensor between the limits of the magnet assembly’s stroke. Other
mounting kits are available upon request
Step 3.
Mount positioner at a remote location,