![Avery Weigh-Tronix TT-830 Service Manual Download Page 25](http://html1.mh-extra.com/html/avery-weigh-tronix/tt-830/tt-830_service-manual_3030615025.webp)
25
TT-830 Bench Scale Service Manual
You may use as little as 1% of
full capacity to span the system
but Weigh-Tronix recommends
using as close to 100% of full
capacity as possible.
SPAN
If you press the
SPAN
soft key, follow these instructions:
1.
The current span calibration
weight is displayed. Press
ENTER
to accept this weight or
key in a new one and press
ENTER
. . .
The display prompts you to apply the
test weight load to the scale.
2.
Apply the test weight load to the
scale and press
ENTER
. . .
The indicator determines the span
and tells you when it is done. Above
the text, the display should show you
the correct test weight. If not perform
the span again.
3.
Press any key to return to the
CALIBRATE display.
The soft key group and functions accessed by the
MORE
soft key are
explained on the previous page.
As you try to exit the calibration section the display will ask if you want any
changes saved. Press the
YES
key if you want changes saved,
NO
if you do
not.
This concludes the calibration section of the manual.
There is one more menu that you can access for testing purposes. Hold the
ESCAPE
key for 5 seconds then key in 911 at the prompt. These softkeys
appear:
KEYPAD
This test lets you check each front panel key for proper opera-
tion.
BASES
This key allows you to view the output from the selected base.
(
Local
,
Remote 1
and
Remote 2
, if connected).
For Quartzell bases you will see a screen similar to this:
This screen shows you:
• the serial number of the Quartzell in the currently selected
base
• the raw counts from the cell (which should be stable ±200
counts and increase when weight is applied)
Test Menu
Summary of Contents for TT-830
Page 1: ...TT 830 Bench Scale Service Manual...
Page 2: ...2 TT 830 Bench Scale Service Manual...
Page 29: ...29 TT 830 Bench Scale Service Manual 17 26 18 27 19 28 20 29 21 30 22 31 23 32 24 33 25...
Page 36: ...TT 830 SOLUTION SERIES BENCH SCALE DISPLAY INTERFACE BD DISPLAY ASSY KEYPAD ASSY And MATRIX 36...
Page 38: ...TT 830 SOLUTION SERIES BENCH SCALE SCALES AND BASES DIMENSIONAL OUTLINE FOR 12 x 14 BASE 38...
Page 39: ...TT 830 SOLUTION SERIES BENCH SCALE COM2 INTERFACE CABLE OPTIONS AND PIN OUTS 39...
Page 42: ...TT 830 SOLUTION SERIES BENCH SCALE This Page left Intentionally Blank 42...