18
TT-830 Bench Scale Service Manual
lbs, a weight change over 10 pounds occuring during the
sample time (½ sec. in our example) will disable the
Harmonizer until the weight change during the sample
time drops below 10 lbs.
• TMOUT
Use this key to set Zero Timeout, Tare Timeout, Print
Timeout and Accumulate Timeout. This is the amount of
time the TT-830 will wait for motion to cease and perform
the function after the key is pressed.
For example, if Zero Timeout is set to 3 seconds, when
the
ZERO
key is pressed the unit will zero the scale if
there is no motion. If there is motion and motion ceases
within 3 seconds the unit will zero the scale. If motion
doesn't cease the key press is ignored.
• EXIT
Press this key to go back to the previous soft key set.
Following are detailed instructions for setting these parameters.
If you press the
MOT'N
soft key, follow these instructions:
1.
The current value for the motion
window size, in divisions, is
shown. Press
ENTER
to accept
this value or key in a new value
and press
ENTER
. . .
The current time window in seconds
is displayed.
2.
Press
ENTER
to accept this time
period or key in a new value and
press
ENTER
. . .
The display returns to the
CONFIGURE-MENU2 display.
If you press the
AZT
soft key, follow these instructions:
1.
The current value for the AZT
window size, in divisions, is
shown. Press
ENTER
to accept
this value or key in a new value
and press
ENTER
. . .
The current time window in seconds
for AZT is displayed.
2.
Press
ENTER
to accept this time
period or key in a new value and
press
ENTER
. . .
The display returns to the
CONFIGURE-MENU2 display.
If you press the
FILTER
soft key, follow these instructions:
1.
The display shows the current
value for the number of samples
to average. Press
ENTER
to
accept this value or key in a new
value and press
ENTER
. . .
The display shows the state of the
Harmonizer filtering( ON or OFF).
MOT'N (motion)
AZT (auto zero tracking)
FILTER
The display will ask for a scale
number if Multiscale is enabled.
The display will ask for a scale
number if Multiscale is enabled.
The display will ask for a scale
number if Multiscale is enabled.
Summary of Contents for TT-830
Page 1: ...TT 830 Bench Scale Service Manual...
Page 2: ...2 TT 830 Bench Scale Service Manual...
Page 29: ...29 TT 830 Bench Scale Service Manual 17 26 18 27 19 28 20 29 21 30 22 31 23 32 24 33 25...
Page 36: ...TT 830 SOLUTION SERIES BENCH SCALE DISPLAY INTERFACE BD DISPLAY ASSY KEYPAD ASSY And MATRIX 36...
Page 38: ...TT 830 SOLUTION SERIES BENCH SCALE SCALES AND BASES DIMENSIONAL OUTLINE FOR 12 x 14 BASE 38...
Page 39: ...TT 830 SOLUTION SERIES BENCH SCALE COM2 INTERFACE CABLE OPTIONS AND PIN OUTS 39...
Page 42: ...TT 830 SOLUTION SERIES BENCH SCALE This Page left Intentionally Blank 42...