16
TT-830 Bench Scale Service Manual
If you press the
SERIAL
soft key, follow these instructions:
1.
The display prompts you for
serial port # to configure. Press
ENTER
if displayed port is OK or
key in a new port number and
press
ENTER
. . .
The baud rate code number is
displayed.
2.
Press
ENTER
to accept the
baud rate or key in a new baud
rate code number from the table
below and press
ENTER
. . .
The parity code number is displayed.
Baud Rate Codes
0 = 300
4 = 9600
1 = 1200
5 = 19,200
2 = 2400
6 = 38,400
3 = 4800
7 = 56,700
3. Press
ENTER
to accept the
parity or key in a new parity
code number from the table
below and press
ENTER
. . .
The databits setting is displayed.
Parity Codes
0 = NONE
3 = SET
1 = ODD
4 = CLEAR
2 = EVEN
4. Press
ENTER
to accept the
databits setting or key in the new
databits value (7 or 8) and press
ENTER
. . .
The handshake protocol code
number is displayed.
5.
Press
ENTER
to accept the
handshake protocol setting or
key in a new code number for
the handshake from the table
below and press
ENTER
. . .
The mode code number is dis-
played.
Handshake Protocol Codes
0 = NONE
2 = Xon / Xoff
1 = CTS
3 = BOTH
6.
Press
ENTER
to accept the
mode setting or key in a new
code number from the table
below and press
ENTER
. . .
The EOM (end of message) value is
displayed.
Serial Mode Codes (Port 1)
Serial Mode Codes (Port 2)
0 = BASIC control
0 = BASIC
1 = Keyboard
1 = Keyboard
2 = Disabled
2 = Disabled
5 = Split
6 = Dual
SERIAL
Setting this parameter to SET
will simulate 2 stop bits and no
parity detection.
CTS is a hardware handshake
(ready/busy) which requires
two extra wires in your cable.
Xon/Xoff is a software hand-
shake requiring no additional
hardware.
Summary of Contents for TT-830
Page 1: ...TT 830 Bench Scale Service Manual...
Page 2: ...2 TT 830 Bench Scale Service Manual...
Page 29: ...29 TT 830 Bench Scale Service Manual 17 26 18 27 19 28 20 29 21 30 22 31 23 32 24 33 25...
Page 36: ...TT 830 SOLUTION SERIES BENCH SCALE DISPLAY INTERFACE BD DISPLAY ASSY KEYPAD ASSY And MATRIX 36...
Page 38: ...TT 830 SOLUTION SERIES BENCH SCALE SCALES AND BASES DIMENSIONAL OUTLINE FOR 12 x 14 BASE 38...
Page 39: ...TT 830 SOLUTION SERIES BENCH SCALE COM2 INTERFACE CABLE OPTIONS AND PIN OUTS 39...
Page 42: ...TT 830 SOLUTION SERIES BENCH SCALE This Page left Intentionally Blank 42...