12.
Enter the
Time Server’s IP
address. The printer waits 20 seconds for the server to respond.
The status is displayed within parentheses: “W aiting for Server,” “Time Server Error,” or the
current date and time.
13.
Enter the
Time Zone Adjustment
in hours and minutes, from Greenwich Mean Time (GMT).
This offset varies by location and time zone. For example, Eastern/Standard time is five hours
behind GMT. Use –5:00 for the offset. For an offset of 3.5 hours, use 3:30.
Note:
Changes for Daylight Savings Time are not made automatically. If your time zone
participates in Daylight Savings Time, change the time zone offset accordingly.
14.
Set the
TCP Window
. 10240 is the default.
15.
Set the
TCP Port
. Port 9100 is the default.
16.
Set the
TCP Timeout
(in minutes). The default is 0, which is no timeout.
17.
Set the
Keepalive Timer
(in minutes). The default is 1 minute.
18.
Enable or Disable
IP Receive CheckSum
and
Probe Idle Connections
.
19.
Select
Retry Enable
for LPD/LPR.
20.
Select
Enable Web Authorization Timeout
to make the W eb pages time out after five (5)
minutes of inactivity.
Note:
The time out period is set for five minutes and cannot be changed.
21.
Select
Enable HP Jet Admin
if using HP Jet Admin. No other settings are required for HP
JetAdmin.
22.
Click
Save Changes
to save changes or click
Save/Re-init Network
to save the changes and re-
initialize the network with the new settings. Any changes made on this screen or other screens
do not take effect until you click
Save/Re-init Network
.
This process takes a few minutes.