AVENTICS
| GSU | R402002667–BAL–001–AC | English
14
11 Technical Data
General data
Dimensions
Depending on the stroke;
see product catalog
(www.aventics.com)
Weight
Depending on the stroke;
see product catalog
(www.aventics.com)
Operating temperature
range
0
°
C to +60
°
C
Storage temperature range
25
°
C to +75
°
C
Protection class according
to EN 60529/IEC 529
(sensors)
IP 65. Alternatively IP 67 if
sensors with a threaded
connector are used.
Mounting orientation
Any. If there is a risk of
standing water, the
guided slide unit must be
installed with the outer
sealing strip facing down-
wards.
Operating pressure
1.5 to 8 bar
Speed
Max. 1.5 m/s
Compressed air quality
class
To DIN ISO 8573-1,
class 6, 4, 3 or lower
Solid pollutants:
≤
5
μ
m
Dew point:
≤
3°C
Oil content:
≤
1 mg/m
3
The manufacturer's declaration for the guided
slide unit and the declaration of conformity for the
sensors can be downloaded online from the
AVENTICS Media Center.
Summary of Contents for GSU16
Page 45: ......