Introduction series AV-5000 for LED keypad
The series 5000 alarm panels for LED keypads are simple, easy to customize and
programming.
Series 5000 models
This is an express manual for series 5000 alarm panels for LED keypad supplied as
technical reference; with each alarm panel we provide a short format manual.
Model AV5009_GRND is GSM only SMS messaging and dial, not supports PSTN dial.
Alarm panel AV-5009 supports 8 double zones, replace older models AV-3008, AV-
4008, AV-4009.
For GSM versions refer to the GSM section.
Panels with Gismo (GSM on board) are compatible with LED keypads: AV-701, AV-702.
Not compatible with LCD keypads.
Tips to first time installer
If you are a first time installer, do not hook up any remote sensors at first. The most common
confusion comes about when the
alarm will refuse to arm
, because one or few zones are
“troubled”. Complete the power supply, siren, keypad and strobe wiring, and for the moment
connect ALL the zone terminals to –V. This will simulate a system with all zones looped out
through closed switches. The alarm is supplied already programmed with an “average” list of
settings (default) and can be used straight away, a few of the program locations may have to be
changed to suit the actual sensors and output devices used.
Read this manual carefully, it looks complicated, but all the information is there
Do not power up with battery! Use the DC power for start and testing. Default programming code is 1994, user
01 code is 1234 (01, 02...08)
To start with: Hook up the keypad, connect all zones to –V or apply resistors for 8 zone mode, power-up by
applying DC only
In case the keypad displays ‘8’ and keys not respond verify the minus (-V) wire and other keypad connection
Fast test: Verify “Dial LED" Self Test at Initialization (STI) - Blinks for the first 50 seconds after power on,
confirms panel is operative, from keypad wait to six beeps to confirm communication OK.
Arming is possible if all zones are close, unless delayed zone/s. To test don't enable EOL zone/s.
Arm and disarm the system, when the Status LED light steady (not blinking), enter your master code; 1234
Try the hold-down functions. Hold each key for approximately 2 seconds
Set the system time by holding-down key ‘0’ then ‘1’, set time in 24H format, blinking ‘Set Time’ stop
The default programming is set for siren alarm device that requires 12V to alarm (Bell Mode)
Make sure you are using the Earth terminal
for Grounding; it is not a -V (minus) terminal
Typing six erroneous codes will lock the keypad keys for 30 seconds
In program mode press 200 then 00 to display control panel type & software version
Revision changes
Date
Version
Contains
05-DEC-2021
1.00
First published