3. System Features & Times (00 = No, 01 = Yes)
Address
Feature
Default Address
Feature
Default
D i a l e r F e a t u r e s
A r m / D i s a r m K e y
041
Instant dialing on entry delay (0=No)
01
089
Use last zone (8 /16) as key input (0=No)
00
042
Siren time during dialer report (sec)
Reserved
090
Use last zone as Freeko key input (0=No)
Reserved
043
SVM 1 time during dialer report (sec)
Reserved
091
Key Arm with Home Mode Grp 1 (0=N0)
00
044
SVM 2 time during dialer report (sec)
Reserved
092
Siren 3 Beeps when Disarm by Key
00
045
Total dialer sound report time (sec)
Reserved
093
Reserved
046
Inter calls pause for dialer (sec)
Reserved
094
Delay before reporting AC fail (minuets)
10
047
How many times dialer make a call
03
095
Activate Dialer reporting AC fail (0=No)
Reserved
048
Dialer delay before start dialing (sec)
Reserved
A u t o A r m , C o d e R e s t o r e
049
Test dial tone before dialing (0=No)
Reserved
096
Enter time for Self Arming (24H format)
00:00
050
Wait for dial tone before dialing (sec)
Reserved
097
Reserved
00
051
Dialer anti Jan delay
Reserved
098
Passive Arming delay Max 9, Min 05 mint
00
052
Telephone line test intervals (minutes)
Reserved
100
Arming Momentary Key=01/ Wi-Fi relay
01
053
Telephone line test at disarmed (0=No)
Reserved
101
Instant Arming by press Key 5 (0=N0)
00
054
Rings count before system answers
Reserved
102
Battery Test upon Arming
01
055
Ring Length (unit 10 milliseconds)
Reserved
103
Show LEDs and Display at Home mode
01
056
Ring Cycle (unit 100 milliseconds)
Reserved
104
Tamper Zone/s as 24H zone/s
00
057
Ring Time Out (minimum) seconds
Reserved
105
Reset zones before siren stop (0=No)
00
058
Answer now at phone ring (0=No)
Reserved
106
Codes restore with *
&
# enabled (0=No)
01
059
Bypass answering machine (0=No)
Reserved
107
Display troubled zones even 103=1
00
E x i t & E n t . D e l a y , P u l s e C n t
108
Reserved
060
Fast dialing upon alarm (0=No)
01
109
Enable remote DTMF via telephone
Reserved
061
Reserved
062
Entry delay 1 (seconds)
12
110
Remote Disarm via DTMF Tel (0=No)
Reserved
063
Entry delay 2 (seconds) X 4
00
111
Remote Zone Bypass via DTMF (0=No)
Reserved
064
Exit delay (seconds) X 4
08
112
Reserved
065
Time frame for Pulse Count Zone (sec)
08
113
Enable remote control via PC (0=No)
Reserved
S i r e n F e a t u r e s
114
Remote PC sets the system date (0=no)
Reserved
067
Total siren sound time (minutes)
03
115
Reserved
068
Siren Test on Arming (0=No)
00
116
Enable ON output as Elec. strike trig
Code 7
069
Siren when Tel Line Test fail (0=No)
Reserved
117
Reserved
070
Siren sound On during cycle (sec)
15
118
Output A1 time set (sec)
30
071
Siren sound Off during cycle (sec)
04
119
Activate A1 output at Panic alarm
00
072
Siren at Bell (DC Output) Mode (0=No)
01
120
Activate A1 output at Tamper alarm
00
073
Siren at Self Contained Mode (0=No)
00
121
Activate A1 output follow siren time
01
074
Reserved
122
Activate A1 output via Remote DTMF
00
075
Buzzer 3 beeps when Disarming (0=No)
01
123
Reserved
K e y p a d ( K P ) B u z z e r
O u t p u t s A 2 , S L O & T i m e s
076
Activate buzzer at entry delay (0=No)
01
124
Output A2 time set (minuets)
Reserved
077
Activate buzzer at exit delay (0=No)
00
125
Activate A2 output at Panic alarm
Reserved
078
Activate buzzer at Tel Test Fail (0=No)
Reserved
126
Activate A2 output at Tamper alarm
Reserved
079
Activate buzzer at Home Mode (0=No)
01
127
Reserved
00
080 (1) Activate buzzer keys feedback (0=No)
01
128
Activate A2 output to trig Listen In
Reserved
081
Activate KP Panic keys * & # (0=No)
01
129
Reserved
082
Activate siren at KP Panic (0=No)
00
130
Activate SLO output at Panic alarm
01
083
Activate Tel Dialer at KP Panic (0=No)
01
131
Activate SLO output at Tamper alarm
00
084
Activate KP Buzzer at Panic (0=No)
00
132
Activate SLO output at Tel Line Fail
Reserved
085 (2) Activate Panic keys at AV707-B (0=No)
Reserved
133
Activate SLO output via Remote DTMF
Reserved
086
Reserved
134
Reserved
087
Number of Beeps for Chime Zone
03
135
Reserved
00
088
Reserved
136
Activate SLO2 output as Smoke Reset
Reserved
137
Reserved
(1) LED keypad only