20
For easier detailed alarm history, use the downloaded from panel to remote computer.
History queue log of up to 250 events are displayed at panel keypad and in the
EasyLoad
PC software.
4.
0
Shunt
and
1
Siren
Display and Setting of System Time:
Hold down key ‘0’ and
then hold-down key ‘1,’ 3 LEDs will blink. System time displayed in 4-digit format: 1230.
To set new time, hold down key ‘0’ and then hold down key ‘1.’ Do not wait for time
display; enter the new time in 24-hour format. The local clock time is not stored in
system memory; clock must be adjusted after power-up. After powering-up system, time
is reset to 00:00, ‘h’ will be displayed to remind user to set time; ‘h’ will disappear after
setting the time. If Auto-Arming enabled the clock setting is form user Programming
mode only, refer to Auto-Arming section.
For clock setting during winter/summer time changes (set by end user):
Hold down key “0" press key "1" then again 1 - increases hours by one
Hold down key “0" press key "1" then key “0” - decreases hours by one
5.
0
Shunt
and
2
Shunt
Display
Display and Setting of System Date:
Hold down key ‘0’ and
then hold-down key ‘2’; 3 LEDs will blink. Enter date: ‘dd mm yy.’ The up and download
PC software displays time and date, along with event history.
The local date is stored in system memory; adjust date after long power-fail.
Years 00 through 77 translated as 2000 to 2077
6.
0
Shunt
and
3
Status
Concise History of Tampered Zones:
Hold down key ‘0’ and
then hold down key ‘3’ to display the Tampered zone alarm sequence.
New alarm will create a new history event instead of old one.
7.
0
Shunt
and
4
Delay
Delete
Reset Events Memory (history):
Not available.
Instead, during the installer-programming mode, clear history by command 200+04.
8.
0
Shunt
and
5
Chime
Display Last 2 Users:
Hold down key ‘0’ and then hold down
key 5 to display user number and System opening or closing time.
‘o’ is displayed for Opening (Disarming); ‘c’ is displayed for Closing (Arming).
9.
0
Shunt
Press
(not hold-down)
and press
9
Reset
(not hold-down), will display ‘-’ to
cancel all Bypassed Zones.
*
#
Keypad Panic
Keys
PANIC BUTTON
Holding down * and # keys will trigger Panic alarm. H will be displayed (zone ‘H’).
To cancel Hold-Down function accessed by keys [0], [6] and [7]; Hold-Down key 9 (Reset).
To quit zero hold-down functions, hold-down ‘9
Summary of Contents for AV-5000 GSM
Page 32: ...32 ...