Warning, siren/s current should not exceed 0.3 Ampere
Bell mode is factory default; in Bell mode install a 12V DC siren, which contains sound
driver or electronic modules that powered by 12V DC.
Bell Mode converts Siren outputs into 13.6V DC outputs (no sound is issued).
Bell mode is applicable for driving self-powered sirens or bells, or combined sirens and
strobes.
Siren configuration programming address
Address
Feature
Explanation
068
Siren test/beep upon arming
Sounds a short beep to indicate arming
072
Bell mode
Send 12V DC to drive the siren
073
Self contained siren
Send 12V at idle, drop to zero V at alarm
092
Siren 3 beeps when disarm by
key
Sounds 3 short beeps to indicate
disarming
070, 071
Siren duration times
Configures the siren times
2.7 Back-Up Battery
Make sure to connect the Battery in the
correct polarity! Wrong polarity may
cause explosion.
The system's Red wire is the positive pole (+) and the Black wire is the negative pole (-).
The battery will provide power back up in case of AC power failure.
Connect back-up battery to ensure proper operation of the system.
Recommended battery: 7 Amperes per Hour (AH), 12V (sealed lead acid) type.
A 7.2 AH battery backs up the control panel and a single keypad for approximately 6-8
hours, depends on total system current consumption.
Series 5000 panels accommodates a battery of up to 12V–9 AH maximum.
An Electronic Fuse rated at 2.5A protects the battery.
Add an external power supply for installation with over three LED keypad and/or if over
ten high current sensors alarm system. Refer to Av-Gad AV-21, AV-40 power supply and
charger.
The 4AH–12V battery fits in the ABS box, but the door is too tight, why? Note the
following:
1. Notice two small bulges on the ABS box door (designed for supporting and hold
the battery) may displace the battery; place the battery between the bulge and not
on it
2. Make sure that the battery is not laying on the income wiring
2.8 DC Power Supply 5014TER
Each alarm panel
requires DC 14V
, factory item 5014TER. Check DC or solar voltage
level before connecting the DC power source or solar.
When using DC sources make sure to connect the power in the correct polarity! When
solar panel removed connects other power source like 5014TER.
Don't connect higher
voltage then 14V DC power source to prevent internal heat up and total lost.