17
There is no "beep" at the keypad until an alarm occurs, or until Group Bypass is
canceled.
When the keypad LEDs turns off after Arming (requires programming), touching the
keypad will activate the LEDs for 5 seconds.
5.3 Key Zero Hold-Down functions & Events History
To get last 10 events by SMS: Hold down 6 than hold down key 4.
1.
0
Shunt
Key 0
Concise Alarm History
: Hold down key ‘0’ to display the last alarm
sequence.
2.
0
Shunt
and
0
Shunt
Detailed Events History (requires programming):
Hold
down key ‘0’ and again hold down key ‘0’ to display up to 36 events, including: System
opening and closing by user number, opening or closing time, alarming zone and AC fail.
By holding-down key
0
Shunt
twice, 3 LEDs start blinking, to indicate a special operation
mode. The events are displayed from the most recent event to the oldest.
By holding-down key
0
Shunt
twice, 3 LEDs start to blink, indicating a special operation
mode. The events are displayed from the most recent to the oldest event. Erasing both
detailed and short history; at program mode press 200 then 04.
Events at AV-701/2 keypad are displayed as following:
XX - Event number (from 01 to 250), then HH_MM (Hour and Minutes) Event Time,
Event Type (alarm or opening/closing).
Translate the display as following:
‘u’ (user number 1 to 8),
‘o’ or ‘c’ - opening or closing
Zone causing alarm will blink twice
tX - Tamper alarm from zone causing the alarm (X)
H - Panic Alarm
Events at AV-701/2 keypad and computer events log displayed as following:
'CE' - Communication to central station failure
'PE' - Keypad locked because Password Error
'Lb' - Low battery
'CC’ - Telephone line fault
Note:
Three lines (
) indicate power fail. During history events AC power fail is
displayed.
For example:
01 2 2 _ 2 4 u 1 o 02 2 3 _ 0 5 7 7 03 2 3 _ 3 5 H H 04 0 0 _ 0 8 u 1 c -
Sign then long beep
Event 01
Time
User 1
Opening
Event 2 Time Alarm Zone 7 Event 3 Time Alarm Zone H Event 4 Time User 1 Closing
Display
indicates end of History
Zone No. blinks twice
Figure 6: Alarm Events as Displayed on keypad
During zone number display, keypad display blinks twice to indicate the zone number.