22
Status LED-Green AV-5000 alarm panel
Off
System Disarmed
Blink slowly
Some zones are open
ON steady
All zones OK
Blink fast
Some zones have been tampered
Shunt LED-Orange AV-5000 alarm panel
ON steady
Some zones are bypassed
Blink slowly
Group bypass entered
Blink slowly
8 seconds after Armed with Group Bypass
Fire LED-Red
AV-5000 alarm panel
Blink slow
Warning before Fire alarm
Blink fast
During and after Fire alarm
Note: At alarm time Troubled Zones are displayed at the Keypad.
Red ARMED/ALARM Indicator
- Lights up when system is armed, blinks after an
alarm is triggered at any zone. Blinking indicates alarm history in memory.
Green STATUS Indicator
- Blinks when zone/s are troubled and remains lit as long
as zones are clear, rapid blinking during Tamper alarm.
Yellow SHUNT (Bypass) Indicator
- Lights up upon zone bypass.
(Note: may light automatically upon arming if Auto Bypass was programmed).
The indicator also lights up and blinks if a Group Bypass was entered by pressing ‘0’
twice.
Red FIRE (Trouble) Indicator
- Rapid blinking when a Fire Zone is troubled.
Two LEDs Flashing (Left Most LEDs)
- In user code programming mode, rapid
blinking indicates code or code index to be entered. In Installer programming mode, it
indicates address entry.
In Disarmed mode, the two left-most LEDs bl zone number display indicate 24H-
alarm mode.
Three LEDs Flashing
- In Disarmed mode, rapid blinking indicates AC power
failure. AC power fail event is displayed in Events. In Armed mode, rapid blinking
indicates system restored after AC Power Failure mode.
During programming Follow-Me Telephone Number, three flashing LEDs indicate to
enter a new telephone number.
Four LEDs Flashing
- Upon holding-down key ‘8,’ the system is ready for code
to be entered. (Same LED indication when code is expected for Bypass via code).