Status LED-Green  AV-5000 alarm panel 
Off 

System Disarmed 

Blink slowly 

Some zones are open 

ON steady 

All zones OK 

Blink fast 

Some zones have been tampered 

 

Shunt LED-Orange  AV-5000 alarm panel 
ON steady 

Some zones are bypassed 

Blink slowly 

Group bypass entered 

Blink slowly 

8 seconds after Armed with Group Bypass 

 

Fire LED-Red 

AV-5000 alarm panel 

Blink slow 

Warning before Fire alarm  

Blink fast 

During and after Fire alarm 

Note: At alarm time Troubled Zones are displayed at the Keypad. 
 

  Red  ARMED/ALARM  Indicator

  -  Lights  up  when  system  is  armed,  blinks  after  an 

alarm is triggered at any zone. Blinking indicates alarm history in memory. 

 

 Green STATUS Indicator

 - Blinks when zone/s are troubled and remains lit as long 

as zones are clear, rapid blinking during Tamper alarm. 

 

 Yellow SHUNT (Bypass) Indicator 

- Lights up upon zone bypass. 

(Note: may light automatically upon arming if Auto Bypass was programmed). 
The  indicator  also  lights  up  and  blinks  if  a  Group  Bypass  was  entered  by  pressing  ‘0’ 
twice. 

 

 Red FIRE (Trouble) Indicator

 - Rapid blinking when a Fire Zone is troubled.  

 



  Two  LEDs  Flashing  (Left  Most  LEDs)

  -  In  user  code  programming  mode,  rapid 

blinking  indicates  code  or  code  index  to  be  entered.  In  Installer  programming  mode,  it 
indicates address entry. 
In Disarmed mode, the two left-most LEDs bl zone number display indicate 24H-
alarm mode. 

 



  Three  LEDs  Flashing

  -  In  Disarmed  mode,  rapid  blinking  indicates  AC  power 

failure.  AC  power  fail  event  is  displayed  in  Events.  In  Armed  mode,  rapid  blinking 
indicates system restored after AC Power Failure mode. 
 
During  programming  Follow-Me  Telephone  Number,  three  flashing  LEDs  indicate  to 
enter a new telephone number. 



 Four LEDs Flashing

 - Upon holding-down key ‘8,’ the system is ready for code 

to be entered. (Same LED indication when code is expected for Bypass via code). 

Summary of Contents for AV-5000 GSM

Page 1: ...rm Control panel Communicator 8 zones Installation and Operation Express Manual Version 1 00 Edition I This product is subject to continuous enhancements and therefore specifications may be changed or altered without prior notice Item 4765E_LED A3BKE Rev 04 27 Feb 2022 ...

Page 2: ...main codes 8 codes 12 4 2 Enter user programming Set New User Code 13 4 3 SMS and dialer number entry by user 13 4 4 Installer Programming mode Code change code 33 13 4 6 Auto Arming Passive Auto Arming 14 5 LED Keypad Hold down Functions 14 5 1 Hold Down Functions 14 5 2 Group Bypass home mode 16 5 4 LED Dual Keys Hold Down Functions 18 5 5 Keypad Functions at location 200 18 5 6 Keypad Main Oper...

Page 3: ...l sensors and output devices used Read this manual carefully it looks complicated but all the information is there Do not power up with battery Use the DC power for start and testing Default programming code is 1994 user 01 code is 1234 01 02 08 To start with Hook up the keypad connect all zones to V or apply resistors for 8 zone mode power up by applying DC only In case the keypad displays 8 and ...

Page 4: ...ions 5 Chime Instant Arming by pressing key 5 requires programming 0 Shunt Zone Bypass by pressing key 0 followed by entering the Zone number s Group Bypass explained in the keypad section For full details refer to the keypad section in this manual and the keypad manual The AV 5000 LED alarm panel board carries a specific identification label refer to wiring diagram that indicates the software ver...

Page 5: ...urrent it protects the circuit by going from a low resistance to a high resistance state that reduces the current to a level that s safe for the circuit elements The change in resistance is the result of a rapid increase in the temperature of the device Like traditional fuses Electronic Fuse devices interrupt the flow of dangerously high current However unlike traditional fuses they automatically ...

Page 6: ...d 8 The EOL loop protects the zone lines against tampering Figure 2 1 None EOL mode zone wiring 2 2 Tamper per zone EOL wiring Tamper alarm per zone is not available with AV 5009 in eight 8 zones mode The V is common for EOL resistors Av Gad 3000 Series panel V Z1 Eye Spy II PIR 2 2K 4 7K Notice wires to V Colors 2 2K Colors 4 7K Red Red Red Yellow Purple Red Figure 2 2 EOL mode zone wiring ...

Page 7: ...l Each keypad has four terminal wires Power connect to Aux Power System Data connect to OR Power connect to Aux Power System Strobe connect to YE Figure 2 3 W iring more then one keypad Wire length for each Keypad should not exceed 100 meters when using 0 5 mm2 wires For longer then 100 meters 320 feet keypad wiring contact manufacturer s consultant For AV 701 702TP keypad with tamper run five 5 w...

Page 8: ...8 Figure 2 4 W iring LED keypad to control panel Wiring terminal of keypad type AV 702 in above figure and for AV 701 keypad are identical ...

Page 9: ...protect the wires from being tampered Figure 2 5 Wiring PIR or similar detector to control panel 2 6 Siren Wiring The siren output is protected by Electronic Fuse Av Gad Bella sirens are recommended for high efficiency and low current consumption The 5000 series is compatible with 12V DC sirens at maximum 0 3A Higher current damage the siren driver Connect the Tamper switch to 24H zone requires pr...

Page 10: ...er operation of the system Recommended battery 7 Amperes per Hour AH 12V sealed lead acid type A 7 2 AH battery backs up the control panel and a single keypad for approximately 6 8 hours depends on total system current consumption Series 5000 panels accommodates a battery of up to 12V 9 AH maximum An Electronic Fuse rated at 2 5A protects the battery Add an external power supply for installation w...

Page 11: ... line Dialing mode is programmable refer to programming sheet addresses 084 Connect the telephone line to TEL LINE terminal if handsets connected to same line connect them to PHONES when system attempts to dial the PHONES is disconnected Do not connect to ISDN or other digital telephone system Most ISDN converters contain an Analog line connect the Analog line of the ISDN to the panel TEL LINE ter...

Page 12: ...18 Regular Telephone number 6 4 System Codes 4 1 Description of main codes 8 codes Up to eight 8 different Arm Disarm codes and one installer dealer code are available each code consists of 1 to 6 digits Factory Installer programming code is 1994 Installer dealer user is 09 Do not use 0 as the first digit in a code Do not use 5 five as first digit in a code number if Instant Arming via key 5 was p...

Page 13: ...ry default 1 2 3 4 3 If code is valid u small U is displayed 4 The 2 left most LEDs blink to indicate that the system is waiting for a new user code index user 01 to 08 to be entered 5 Enter the code index from 01 to 08 01 for code No 1 02 for code No 2 etc 6 The 3 right most LEDs blink to indicate that the system is waiting for a new code from 1 to 6 digits to be entered The code is voided if use...

Page 14: ...le Automatic Arming program 0000 If Automatic Arming is programmed the system time can be set only via User Programming Mode Hold down key 1 and then HHMM setting system time hold down 8 and then HHMM setting auto arming time HH hours MM minutes Automatic Arming will operate even if the control panel is currently in alarm When the Automatic Arming programmed time arrives the system starts at a 30 ...

Page 15: ...d Follow Me Telephone Number Without Dialing Hold down key 6 Follow Me telephone number programming Hold down key 6 then hold down 6 again Programmed Telephone number Verification Display and Dial 4 telephone numbers Hold down 6 then hold down 7 number not displayed Display programmed telephone numbers without dialing Within few seconds text will appear on the display followed by the programmed Fo...

Page 16: ... programming 4 Resets Day Zone Alarm at Keypad 5 Exits Programming mode features telephone numbers etc To exit programming mode hold down key 9 5 2 Group Bypass home mode Group bypass provides bypassing of few zones by short keys entry Group Bypass is operative only if System is armed within 60 seconds from the entry of this feature Yellow LED will flash and h Home displayed for 1 second in confir...

Page 17: ...rom the most recent to the oldest event Erasing both detailed and short history at program mode press 200 then 04 Events at AV 701 2 keypad are displayed as following XX Event number from 01 to 250 then HH_MM Hour and Minutes Event Time Event Type alarm or opening closing Translate the display as following u user number 1 to 8 o or c opening or closing Zone causing alarm will blink twice tX Tamper...

Page 18: ...et to Use Mode normal operation mode Clearer History events are available when using the download For easier detailed alarm history download events log from panel to the remote computer History queue log of up to 250 events is displayed at panel keypad and in the EasyLoad PC software not available for version 1 10 5 4 LED Dual Keys Hold Down Functions 1 st key hold down 2 nd key hold down Function...

Page 19: ... Beep Short events log history 0 Shunt Hold Down Long Beep 1 o Time setting required 0 Shunt 1 Siren Hold Down FIRE SHUNT STATUS ARMED Long Beep TIME Date setting required 0 Shunt 2 Shunt Display Hold Down FIRE SHUNT STATUS ARMED Long Beep DATE Panic Hold down both keys Keypad Panic FIRE SHUNT STATUS ARMED Long Beep H Bypass zone 3 example 0 Shunt 3 Status FIRE SHUNT STATUS ARMED Long Beep 3 Group...

Page 20: ...splay Display and Setting of System Date Hold down key 0 and then hold down key 2 3 LEDs will blink Enter date dd mm yy The up and download PC software displays time and date along with event history The local date is stored in system memory adjust date after long power fail Years 00 through 77 translated as 2000 to 2077 6 0 Shunt and 3 Status Concise History of Tampered Zones Hold down key 0 and ...

Page 21: ...ving door opening Seven confirmation beeps Arming of System with Instant Fire or 24H troubled zones Five warning beeps troubled zone display Feature programming Two confirmation beeps Follow Me number programming Two confirmation beeps During alarm requires programming Intermittent beep until alarm reset When the buzzer is ON it will sound while the keys 0 and are being held down When the buzzer i...

Page 22: ...tor Lights up upon zone bypass Note may light automatically upon arming if Auto Bypass was programmed The indicator also lights up and blinks if a Group Bypass was entered by pressing 0 twice Red FIRE Trouble Indicator Rapid blinking when a Fire Zone is troubled Two LEDs Flashing Left Most LEDs In user code programming mode rapid blinking indicates code or code index to be entered In Installer pro...

Page 23: ...mself Erasing phone number by hold down key 9 Each Tel Number Maximum 16 digits or and At address 008 enter the SMS provider center number To insert in the phone number Hold down keys and as panic A will be displayed For central phone systems add Pause during dialing hold down key 0 add pause only at add 008 not at address 009 010 Part 2 Main hold down commands Key 1 Hold down test siren Key 2 Hol...

Page 24: ...lephone Reserved 061 Reserved 062 Entry delay 1 seconds 12 110 Remote Disarm via DTMF Tel 0 No Reserved 063 Entry delay 2 seconds X 4 00 111 Remote Zone Bypass via DTMF 0 No Reserved 064 Exit delay seconds X 4 08 112 Reserved 065 Time frame for Pulse Count Zone sec 08 113 Enable remote control via PC 0 No Reserved Siren Features 114 Remote PC sets the system date 0 no Reserved 067 Total siren soun...

Page 25: ... 4 5 6 7 8 Siren Output Zone 067 248 1 2 3 4 5 6 7 8 249 1 2 3 4 5 6 7 8 A1 output Zone 252 1 2 3 4 5 6 7 8 253 1 2 3 4 5 6 7 8 Reserved 256 257 SLO output Zone not timed 260 261 Reserved 264 1 2 3 4 5 6 7 8 265 1 2 3 4 5 6 7 8 Reserved 268 269 Reserved 272 273 1 2 3 4 5 6 7 8 Chime Zone 276 1 277 1 2 3 4 5 6 7 8 Pulse count Zone 065 280 281 Panic reports zone by SMS 284 285 Zone without end of li...

Page 26: ...5 Green Zone activated once 298 1 2 3 4 5 6 7 8 299 1 2 3 4 5 6 7 8 Swinger Shut Down 302 303 Normally Open N O Zone 306 305 Delayed Power Up Zone 310 311 Fast response zone 314 315 Factory Default Program is as shown in table Blank Square means no default program SLO Selective Output Values beneath addresses are default programming 8 Powering Up Programming Examples 8 1 Before Powering Up Place C...

Page 27: ...he panel version and status LED light on Hold down keys Press both together during 5 seconds after applying AC sounder beeps during the hold down release keys U letter displayed in confirmation User code No 1 1234 and programming code 1994 will reset to default 8 3 Installer Engineer Programming Examples Power up by connecting AC power with battery keypad LEDs are on 1 Hold down keypad key 8 Progr...

Page 28: ... 24H zone in factory default program this is an Instant Zone 2 Address 220 represents the 24H Zone type for zones 1 to 8 3 Press 220 current value of the address is means blank no 24H zone is programmed Three LEDs will blink and an will be displayed default program 4 To enter the new required value press the address number 220 then enter new value 4 by pressing 4 Delay Delete zone 4 U confirms pro...

Page 29: ...mage to the GSM module Verify the antenna cable is not coiled Process wiring with power down don t insert the SIM card with power on The Gismo has two indication LEDs power and network After power up wait to network LED to slow blinking fast blinking means not connected to GSM network The alarm panel dialer sends SMS with time and date stamped easy to track systems status alarms and troubles Figur...

Page 30: ...play the dial mode LINE or CELL Press 200 then 51 Set panel to dial via PSTN LINE Press 200 then 52 Set panel to dial via GSM not ready yet CELL Series 5000 panels are capable to send SMS via GSM also can dial via GSM when dial via GSM no tune or sound generated by the system 9 3 GSM factory programmed texts Zone 1 Burglary at zone 1 Zone 2 Burglary at zone 2 Zone 3 Burglary at zone 3 Zone 4 Burgl...

Page 31: ...1 X1 MAX 1A V 8 7 6 5 4 3 2 1 V 12V VREF TX C B E VR1 8 21 5 13 30 1 SVM IN E B C C B E LD1 FA2 D10 C7 C12 C14 C20 C26 C16 C17 C34 C29 C18 C32 C43 C42 C41 C44 D3 D12 D13 D18 D17D16 FA1 FA3 JP2 R6 R16 R23 R27 R9 R30 R13 R12 R15 R14 R19 R7 R11 R21 R33 R41 R45 R44 R48 R51 R56 R57 R63 R62 R68 R72 R73 R79 R71 R82 R80 R81 R84 R93 R78 R77 TT1 U3 U2 U14 U8 U11 U7 U12 VA10 D8 U9 R96 R98 R85 R86 R87 R100 R1...

Page 32: ...32 ...

Reviews: