When wiring DC power supply to alarm panel; the (+) connect to the
upper
AC wires
terminal and the (-) to the
lower
AC marked terminal. Verify the ground is connected.
F i g u r e 2 . 7 : W i r i n g p o w e r s u p p l y 1 4 V m a x i m u m
3. Telephone Line (Central Station no available)
3.1 Telephone Line
Dialing sequence: 1
st
dials to central stations (not available in ver 1). 2nd To standard
phones (wired or mobile). If central station not programmed sequence is bypass.
It’s recommended to connect the control panel to an independent telephone line, if a
device is in parallel with the alarm panel, this may grab the call first (like a message
answer/fax) during remote up and download and remote DTMF. Don’t connect fax or
answering machine in parallel on the same telephone line.
Dialing mode is programmable (refer to programming sheet addresses 084).
Connect the telephone line to ‘TEL-LINE’ terminal, if handsets connected to same line
connect them to ‘PHONES’, when system attempts to dial the ‘PHONES’ is
disconnected.
Do not connect to ISDN or other digital telephone system. Most ISDN converters contain
an Analog line; connect the Analog line of the ISDN to the panel TEL-LINE terminal.
If the PSTN is DSL/ADSL type connect a dedicated lien filter supplied by local Telecom
Company, or Av-Gad AV03 high end ADSL filter.
In tropical areas order the Surgo protection module or specific alarm models to fit.
3.2 AV-5000 with GisMo module
The GisMo module sends SMS for alarm and other events like AC fail, low battery,
through GSM network
To identify the GSM; The Gismo PCB board (refer to fig. 1) with antenna plug located at
the let-upper side in the main control panel case.
For full detail refer to the AV-5000 GSM appendix.