16
Hold-down key 6 and then key 1, before the computer and modem connect (dial) the
control panel. The panel will acknowledge the command with two beeps and display an
‘A.’ The feature remains active for 5 minutes after entered, enabling to remotely program
(from remote computer) the panel.
Other possibility to connect to a system connected on same line with a fax or answering
machine is to use the “Answer machine bypass” feature.
Test
7
Key 7
FAULT FIND
Fault Find enables testing of all detection devices.
Fault Find mode is accessible only during 15 seconds following System Disarm.
24H, Fire or Panic alarm will stop Fault Find mode.
Hold down key 7.
Open and close each zone to test the zone regularity. A one-second beep confirms
detection of zone opening. Three beeps indicate zone closing.
Quit Fault Find mode by arming the system.
8
Program
Key 8
PROGRAM
Key 8 accesses ‘Program’ mode and user code programming (followed by password)
9
Reset
Key 9
RESET.
‘Reset’ performs the following functions:
1.
Cancels last Keypad entry
2.
Stops the communication test (triggered by hold-down key 6)
3
Activates output 2 for resetting the Smoke Detector (requires programming)
4.
Resets Day Zone Alarm at Keypad
5.
Exits Programming mode (features, telephone numbers, etc.).
To exit programming mode hold down key 9.
5.2 Group Bypass (home mode)
Group bypass provides bypassing of few zones by short keys entry.
Group-Bypass is operative only if System is armed within 60 seconds from the entry of
this feature. Yellow LED will flash and ‘h’ (Home) displayed for 1 second in confirmation.
0
Shunt
then hold-down
1
Siren
or
2
Shunt
Display
.
Group Bypass with Arming.
Two
bypass groups are available. Set Group Bypass at address 232-236; after selecting the
Group Bypass, system is armed (without code entry), followed by Red LED (arm) and
Orange LED (indicates zone/s bypassed) on.
To bypass 1
st
group: Press “0” and hold-down “1”, “A” is displayed, Yellow LED will flash
To bypass 2
nd
group press ”0” and hold-down “2”, “b” is displayed, Yellow LED will flash
To bypass both groups press “0” and hold-down “0”. “C” is displayed. Yellow LED will
flash, then the Armed LED lights-up in confirmation.
When Group Bypass is selected, the sounder and LEDs react as follows:
Shunt LED stops blinking 8 seconds after Arming, (prevents LED light from disturbing
sleepers near the keypad).
There is no exit/entry delay-warning sounder; also the keys beep disabled (prevents
noise considering sleepers). At Group Bypass mode the keys entry are not generating
keypad's beeps.