1. Overview
14
© Copyright Reserved Autonics Co., Ltd.
i. -|Transparent setting guide|-
1.3
Ordering information
SF
L
-
-
①
②
③
④
⑤
⑥
Item
Description
①Model
SF
Safety component
②Model type
L
Light curtain
③Function
No mark
Standard type
A
Advanced type
④Detection capability Number Minimum size of detection object (unit: mm)
⑤Number of beams
Number
The number of optical axes
⑥Korea safety
certification
No mark
S-mark
A
KCs (industrial robot protection device)
1.4
Feature comparison
(
●
:
supported (available to the detailed setting)
○: supported (not available to the detailed setting)
×: not supported)
Classification
Function
SFL Series
(standard type)
SFLA Series
(advanced type)
General functions
Mode and status
○
○
Self-test
RS485 communication
(between emitter and receiver)
Monitor light incident level
OSSD output
Mutual interference prevention
Safety-related
functions
Interlock
○
Lockout reset
○
○
External device monitoring (EDM)
○
Muting
○
Override
○
Blanking
(Fixed blanking and floating blanking)
×
Reduced resolution
×
Other functions
Series connection
○
○
Select sensing distance
Select NPN or PNP
External test (light emission stops)
※1
Auxiliary output (AUX)
○
Lamp output (Lamp)
○
PC connection
○
※
1: In case of external test, it can be set by wiring.
※
When setting with the switch, you can select either activated or deactivated state.
※
When connecting to a PC, you can set the details besides selecting to enable or disable the functions via atLightCurtain.
For more information, refer to the “user manual for atLightCurtain.”
※
For more information on the general functions, refer to the "4. General functions".
※
For more information on the safety-related functions, refer to the "5. Safety-related function".
※
For more information on the other functions, refer to the "6. Other functions".