5. Safety-related function
79
© Copyright Reserved Autonics Co., Ltd.
i. -|Transparent setting guide|-
ii. The OSSD output remains ON state when the number of discretely blocked beams is less than the ignored beams.
OSSD
ON
Function activated
OSSD
OFF
(Exceed ignored beams)
Function activated
(2) Setting example of series connection
In case of the series connection, the number of ignored beams set by the master is applied to the slaves.
The figure below is an example when the ignored beams are two.
Slave
Master
OSSD
ON
Function activated
OSSD
OFF
(Exceed ignored beams)
Function activated
Emit
ter
Rec
eiv
er
Rec
eiv
er
Emit
ter
5.7.1 Change settings
Only SFLA (advanced type) supports atLightCurtain to change settings.
Function
Setting range
Factory default
Setting item
atLightCurtain
Setting switch
Reduced
resolution
Reduced resolution function Enable/Disable
Disable
○
-
Ignored beams
1-3
1
※
The reduced resolution cannot be set with the muting and blanking function, be sure to active the reduced resolution
only when these are deactivated.
※
As the detection capability is changed, calculate the safety distance again to ensure the minimum safety distance.