7 Driver Unit Descriptions
34
© Copyright Reserved Autonics Co., Ltd.
7.2
Switches
7.2.1
Function Selection DIP Switch
Set rotation direction, pulse input method, motor gaion and torque mode.
Function
ON
OFF
Applied setting
moment
1 DIR
Rotation direction
CCW
CW
Right after
setting ends
2 1P/2P
Pulse input
method
1-pulse
input
method
2-pulse
input
method
3 GS H/L Motor GAIN setting Inertia
GAIN
Standard
GAIN
When motor is
stopped
4 TM
Torque mode
Torque
mode
Standard
mode
For more information of each function, refer to ‘10 Driver Function’.
7.2.2
Resolution Setting Switch
Set the resolution of driver.
Setting PPR
Resolution Setting PPR
Resolution
0 500
2.5
5
3600
18
1 1000
5
6
5000
25
2 1600
8
7
6400
32
3 2000
10
8
7200
36
4 3200
16
9
10000
50
Modified setting values are not applied in the running status and the values will be applied
after motor stopped.