1 Product Overview
14
© Copyright Reserved Autonics Co., Ltd.
Regenerative resistance
Connect Pin No. 1, 2 on power connector (CN2).
Use in condition of the high inertia load or the short deceleration time.
Forced cooling is required in condition of high surface temperature of regenerative resistance.
Model
Specifications
Manufacture
IRC100
●
Resistance: 100
Ω
±5 %
●
Specified power: 60 W(standby),
100 W(heatsink attached)
RARA Electronics Corp.
Noise fliter for power
Connect the power to suppress external noise.
- The wires should be connected as short as possible and grounded.
Model
Specifications
Manufacture
RNS-2006
●
Specified power: 250 V
●
Specified current: 6 A
●
Max. leakage current: 1 mA
Orient Electronics
Surge protector
Protect the product from erxternal nois and surge by connectiong power.
Model
Specifications
Manufacture
LT-C12G801W
●
Nominal discharge current: 2500 A
●
Max. discharge current: 5000 A
●
Voltage protection level: 1.5 kV
OTOWA Electric Co. Ltd
Be sure to disconnect the surge protector when testing internal pressure.
It may result in product damage.
Noise filter for signal line
Connect to wiring to suppress external noise.
- Depending on frequency, filtered noise may different.
Applications
Specifications
Manufacture
Motor wire
28A5776-0A2
Lairdtech
Power wire
28A5131-0A2