8 Electromagnetic Brake
42
© Copyright Reserved Autonics Co., Ltd.
8.1
Brake Connection
Connect the brake connector (CN4) to motor brake connector and input auxiliary power with
24 VDC
ᜡ
.
When connecting the brake, use AWG22 cable or over for connection.
8.2
Brake Operation
The auxiliary power 24 VDC
ᜡ
input is required to release brake. When the auxiliary power
does not input, Brake error (
ED
) alarm occurs. For more information, refer to ‘11.1 Alarm’.
When Servo is On, brake is released automatically.
The brake remains lock inn all status except Servo On status.
※
Brake lock is manually controllable using the Brake ON/OFF input signal.