Owner Installation Instructions
Easy Slider - Sliding Gate Opener
7
The ALPS technology calculates the gates travel limit positions and stores it in memory. If the gate is moved
manually during power failure, the ALPS will re-align the gate limits transparently during the first operations
after power is restored and stop at the correct limit position.
During installation, a hand held transmitter can be used when setting the gate travel limits. This allows the
installer to closely monitor and control the gates movement from any position rather than having to be within
arms reach of the console.
ISS (Intelligent Safety Obstruction System)
Should the gate hit an obstacle while it is performing a close cycle, or be restricted in some
manner, it will automatically reverse. The amount of force the gate should encounter before
reversing is automatically adjusted by the control system during the initialisation of
the automatic opener. The gate will also stop if restricted whilst opening. The Safety
Obstruction Force should be checked at least once a month. See installation manual
for instructions.
Status indicator
The console displays the status of the opener on the LCD screen. When the MAIN
SCREEN is displayed, the current position of the gate or the result of the last
movement can be viewed. The display will also show the count down progress of
auto-close timers. Any active input will also be displayed along with the state of
various features such as periodic service, battery backup operation and vacation
mode.
Control of lock and lights
The incorporated controller has dedicated outputs for operating a electric lock
and warning or courtesy lights. The timing of these outputs can be adjusted to
suit your needs. In addition a button on a remote control can be coded to operate
the light output.
Extensive operating modes via control inputs and remote control
The integrated controller can be configured to operate in many different ways via
its seven (7) control and safety inputs which include P.E, OPEN, STOP, CLOSE, OSC,
SWIPE and PEDESTRIAN.
Remote control operation is provided with each transmitter’s button being able to be
configured to operate one of OSC, PEDESTRIAN, SWIPE, CLOSE, OPEN, STOP, LIGHT or
VACATION functions.
The controllers functionality is further enhanced by 4 auto-close modes, 3 P.E response modes and
two pedestrian response modes.
Battery backup and solar operation
The opener can be fitted with optional battery backup or solar chargers to provide operation during power
outages or at unpowered sites.
Manual operation
The opener is equipped with a unique manual disengaging device. If the power to the opener is disrupted
for any reason the gate can disengaged via a key lock located on the operator. This will allow you to manually
open or close the gate.
Features