10
Easy Slider - Sliding Gate Opener
Owner Installation Instructions
Drive unit installation
Mounting the drive unit
The Drive Unit mounting holes are slotted for fine adjustment of pinion gear and gate rack alignment. Follow
the procedure below to ensure final adjustments can be made later.
We recommend that four 8mm (
5
/
16
”) or 10mm (
3
/
8
”) loxins and bolts are used to secure the Drive Unit into
position. These loxins usually require a 16mm (
5
/
8
”) masonry drill bit (if drilling concrete).
1. Prior to mounting of the driver unit determine the distance from the gate to the outer edge of the rack (ie the rack
width) to the datum line (see
Fig. 03
and
Fig. 04
). For the ATA plastic racks the width is 40mm. The rack distance
may vary depending on the type of rack used. If you must use a different rack, make sure that it is Module 4.
2. Mark a line 78mm parallel to the face of the gate for the mounting holes when using the ATA plastic rack.
When using a non ATA rack, add your rack width (and spacers if required) and 38mm and mark a line this
distance from the face of the rack (see
Fig. 03
).
3. Then mark another line 100mm from the first line (see
Fig. 03
).
4. Open the gate to the desired open position. Mark a line at right angle to the gate 120-150mm from the open
edge of the gate for the mounting holes.
5. Then mark another line 268mm parallel to this line (see
Fig. 03
).
6. Place the Drive Unit in position where the lines intersect to check the mounting position. If satisfied with the
position remove the Drive Unit.
7. Drill the four mounting holes where the lines intersect.
8. Hammer the loxins into position. Place the Drive Unit into position and fix with the four bolts so that you are
still able to move the Drive Unit.
03
fig
R
ac
k
w
id
th
Datum line
Mounting holes
Gate