Version 6.2
879
February 2011
SIP User's Manual
12. Configuration Parameters Reference
Parameter
Description
[25]
25 = 20.00 dB/sec
[26]
26 = 25.00 dB/sec
[27]
27 = 30.00 dB/sec
[28]
28 = 35.00 dB/sec
[29]
29 = 40.00 dB/sec
[30]
30 = 50.00 dB/sec
[31]
31 = 70.00 dB/sec
Web: AGC Redirection
EMS: Redirection
[AGCRedirection]
Determines the AGC direction.
[0]
0 = AGC works on signals from the TDM side (default).
[1]
1 = AGC works on signals from the IP side.
Web: AGC Target Energy
EMS: Target Energy
[AGCTargetEnergy]
Determines the signal energy value (dBm) that the AGC attempts
to attain.
The valid range is 0 to -63 dBm. The default value is -19 dBm.
EMS: Minimal Gain
[AGCMinGain]
Defines the minimum gain (in dB) by the AGC when activated.
The range is 0 to -31. The default is -20.
Note:
For this parameter to take effect, a device reset is required.
EMS: Maximal Gain
[AGCMaxGain]
Defines the maximum gain (in dB) by the AGC when activated.
The range is 0 to 18. The default is 15.
Note:
For this parameter to take effect, a device reset is required.
EMS: Disable Fast Adaptation
[AGCDisableFastAdaptation]
Disables the AGC Fast Adaptation mode.
[0]
= Disable (default)
[1]
= Enable
Note:
For this parameter to take effect, a device reset is required.
Energy Detector Parameters
Note:
Currently, this feature is not supported.
Enable Energy Detector
[EnableEnergyDetector]
Activates the Energy Detector feature. This feature generates
events (notifications) when the signal received from the PSTN is
higher or lower than a user-defined threshold (defined by the
EnergyDetectorThreshold parameter).
[0]
Disable (default)
[1]
Enable
Energy Detector Quality Factor
[EnergyDetectorQualityFactor]
Determines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest sensitivity and 10
the highest sensitivity. The default is 4.
Energy Detector Threshold
[EnergyDetectorThreshold]
Defines the Energy Detector's threshold. A signal below or above
this threshold invokes an 'Above' or 'Below' event.
The threshold is calculated as follows:
Actual Threshold = -44 dBm + (EnergyDetectorThreshold * 6)
The valid value range is 0 to 7. The default is 3 (i.e., -26 dBm).
Summary of Contents for Mediant 800 MSBG
Page 2: ......
Page 366: ...SIP User s Manual 366 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 372: ...SIP User s Manual 372 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 390: ...SIP User s Manual 390 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 404: ...SIP User s Manual 404 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 616: ...SIP User s Manual 616 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 636: ...SIP User s Manual 636 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 652: ...SIP User s Manual 652 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...
Page 886: ...SIP User s Manual 886 Document LTRT 12804 Mediant 800 MSBG Reader s Notes ...