background image

MC-6011 Keypad

MC-6011 Keypad

MC-6011 Keypad

MC-6011 Keypad

MC-6011 Keypad
Operation &Setup Instructions

Operation &Setup Instructions

Operation &Setup Instructions

Operation &Setup Instructions

Operation &Setup Instructions

- 1 -

- 1 -

- 1 -

- 1 -

- 1 -

Contents

OPERATION: ........................................................................... 2

Turning off a zone or the entire system. ..................................................................... 2
Turning on a zone and changing inputs. .................................................................... 2
Adjusting Volume .......................................................................................................... 2
Controlling Sources ...................................................................................................... 2
Additional Feature Options .......................................................................................... 4
TONE CONTROL ............................................................................................................ 4
TONE PRESETS ............................................................................................................. 4
ALARM CLOCK .............................................................................................................. 4
SLEEP TIMER ................................................................................................................ 5
PARTY

5

VOLUME SET ................................................................................................................. 5
ROOM SCAN .................................................................................................................. 6
KEYPAD LOCK .............................................................................................................. 6

SETUP MENUS ....................................................................... 8

0000

RESET KEYPAD LOCK CODE ................................................................ 8

1110

NIGHT LIGHT ON AND OFF TOGGLE .................................................... 8

1111

KEYPAD TEST MODE ............................................................................. 8

1112

IR RECEIVER ON AND OFF TOGGLE .................................................... 8

1113

BLANKING MODE ................................................................................... 8

1114

MODE BUTTON SETUP .......................................................................... 9

1115

CLOCK SET ............................................................................................. 9

1116

ROOM SET (ZONE SET).......................................................................... 9

1117

1200 BAUD RATE .................................................................................... 9

1118

19,200 BAUD RATE ................................................................................. 9

INSTALLER MODE................................................................ 10

Input Configuration ..................................................................................................... 10
Source Control .............................................................................................................11
IRL-5000

................................................................................................................ 12

ADA Tuner

................................................................................................................ 12

Special CD

................................................................................................................ 12

LVI-3800

................................................................................................................ 13

No Function ................................................................................................................ 13
Source Labels .............................................................................................................. 13
ROOM LABEL .............................................................................................................. 14
MAX ROOM ................................................................................................................ 14
Check Setup ................................................................................................................ 14
Program All ................................................................................................................ 14

Summary of Contents for MC-6011

Page 1: ...e Options 4 TONE CONTROL 4 TONE PRESETS 4 ALARM CLOCK 4 SLEEP TIMER 5 PARTY 5 VOLUME SET 5 ROOM SCAN 6 KEYPAD LOCK 6 SETUP MENUS 8 0000 RESET KEYPAD LOCK CODE 8 1110 NIGHT LIGHT ON AND OFF TOGGLE 8 11...

Page 2: ...etely off All Off the Off button is green It is red only when the zone is off but another zone s is still on To turn off the entire system press and hold the Off button until it flashes Turning on a z...

Page 3: ...automatically tune to the first XM channel in that Genre If you select a specific channel using the button then the Tune Suite will automatically tune to that channel a moment after it has been displa...

Page 4: ...e set to display Alarm Clock and Sleep Timer while the one in the dining room does not display these options This makes it possible for you to tailor the system to your needs TONE CONTROL When in the...

Page 5: ...nt the zone to stay on you must turn the zone off and then back on to cancel the one hour alarm timer If the keypad is locked the snooze function will operate until the alarm mode has been cancelled o...

Page 6: ...system to show the current status for inputs and second source functions but will not allow any buttons to function The setup menus are still accessible when a keypad is locked A user settable 4 digi...

Page 7: ...m the setup menu Press and hold the MODE button for 5 seconds until CODE _ _ _ _ is displayed Using the number Up button enter 0 If you passed 0 you can use the Dn button to go back When 0 is displaye...

Page 8: ...F If the keypad needs to be as dark as possible even when the zone or any other zone is on see blanking mode under code 1113 1111 KEYPAD TEST MODE The MC 6011 can be set to a test mode in which pressi...

Page 9: ...e button to advance to SET DATE and use the and buttons to select the proper date Press the button to SET DAY and use the and buttons to set the right day of the week Press the button to SET 12 24 HR...

Page 10: ...RTYGROUP 4 PARTYGROUP 5 PARTYGROUP 6 PARTYGROUP 7 PARTYGROUP 8 Please note than not all Suite systems have all eight Party Groups Most have only four Party Groups By pressing or you will be able to ad...

Page 11: ...fer to no source selection at all If an IN SOURCE is set to INPUT 0 then it will be skipped over If for example input labels 7 16 IN SOURCE 7 16 are all set to INPUT 0 then the keypad will only scroll...

Page 12: ...s 1 modules 1 3 and the fourth module is set under address 2 module 1 Note that this address setting is not directly tied to the Tune Suite s rotary dip switch address selector as the Tune Suite s 16...

Page 13: ...s of the sources that are connected to the Suite 16 or Suite 8x8 The keypad s display can read up to eleven characters This permits you to define that component by name Whether you are using eight or...

Page 14: ...max room number Changes are immedi ate To exit press the button Check Setup When CHECK SETUP is displayed press the to verify keypad source buttons to input connection source input label number sourc...

Reviews: