CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual
5-3
status:
Displays the status on the system and selected plug-in.
Example #1: In this example, there is no defined system status, it displays the status of the selected plug-in, High
Sensitivity Quad Return Receiver.
Transcend[slot-1]
>status
Slot 1 (HS-QRRX)
ModuleTemp (deg C):
+19.8
OpticalPowerDbm (dBm):
[1] -8.0 [2] -8.0 [3] -8.0 [4] -57.9
alarm:
Displays the alarm status on the system and selected plug-in.
Example #1: In this example, there is 2 defined system alarms and the alarms of the selected plug-in, High
Sensitivity Quad Return Receiver.
Transcend[slot-1]
>alarm
System
PowerAlarm:
Normal
FanAlarm:
Normal
Slot 1 (HS-QRRX)
OpticalPowerAlarm:
[1] MajorLoLo [2] MajorLoLo [3] MajorLoLo [4] MajorLoLo
ModuleTempAlarm:
Normal
DownloadStatus:
Displays the status of current or previous download.
Example #1: This example shows the previous download was completed successfully.
Transcend[slot-1]
>downloadstatus
Successful
slot:
Displays the detected plug-in in each slot.
Example #1: This example shows that the chassis contains an High Sensitivity Quad Return Receiver in slot 1 and
slot 2, 3 and 4 are empty.
Transcend[slot-1]
>slot
Slot 1 - HS-QRRX
Slot 2 - Empty
Slot 3 - Empty
Slot 4 - Empty
CHAPTER 5: