CRAFT LINE INTERFACE (CLI)
5-12
TranScend Chassis – Operation Manual
Example #1: In this example, the module in slot 1 reports its optical switch threshold as 0 dBm.
Transcend [slot-1] > thresholddBm
+0.0
OPinPowerAlarm:
Displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input #1 power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OPinPowerAlarm 1
MajorLoLo
SwitchAlarm:
Displays the alarm status of optical switch. This alarm is raised if switch is in faulty state.
Example #1: In this example, the module in slot 1 reports the alarm status of optical switch as “Normal”
Transcend [slot-1] >switchAlarm
Normal
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal
5.1.2.8 Forward Receiver
The commands in this section are Forward Receiver specific.
ModuleTemp:
Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTemp
+21.4 (deg C)
RFPower:
Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its RF input power reading on input #1 (p.s. primary
optical input).
Transcend [slot-1] >RFPower 1
+3.0
(dBmV)
OpticalPowerDbm:
Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading on input #1 (p.s. primary
optical input).
Transcend [slot-1] >OpticalPwerDbm
+3.0
(dBm)