FRONT PANEL LCD DISPLAY
4-14
TranScend Chassis – Operation Manual
Alarm Menu:
OPin Pwr:
Displays the alarm state of optical input power status.
Press “Right” or “Left” button to cycle through available channels.
Module Temp:
Displays the alarm status of module temperature.
Switch:
Displays the alarm status of optical switch. The alarm is determined based on following conditions-
Severity
Condition
Major
- Optical switch is faulty
- Secondary input is invalid when primary input is below threshold. The
secondary input shall be above the threshold to qualify as a valid signal.
Minor
- Optical switch is on secondary input
Chassis Menu:
Temp(C):
Displays the module’s temperature reading in Centigrade.
Model:
Displays the model name of plug-in module.
HW Ver:
Displays the hardware version information of plug-in module.
SW Ver:
Displays the software version information of plug-in module.
Ser #:
Displays the serial number of plug-in module.
Prev Menu:
Press “Select” will bring the plug-in’s greeting message screen back.
4.3.7.1 Optical Switch Switching Criteria
Switch from primary to secondary:
When the primary optical power drops below the user defined threshold and the
secondary optical power is above the user defined threshold, the optical switch position moves over to the secondary optical
power immediately.
Recover from secondary to primary:
When the primary optical power is above the user defined threshold for one second,
the optical switch recovers back to primary position.
The optical switch position is persistently stored and the unit that recovers from power cycle will restore the optical switch
initial position according to its persistent value. The factory default is primary.
4.3.8 Forward Receiver
Level 1
Level 2
Level 3
Greeting
Setup Menu
Attn(dB)
Save
Prev Menu
Status Menu
Opt Pwr(dBm)
Attn (dB)
RF Pwr (dBm)
Prev Menu